RS485 to DC Current Voltage Converter

China RS485 to DC Current Voltage Converter, Find details about China Signal Data Acquisiton Moudle, Industrial Sensor Signal Test from RS485 to DC Current Voltage Converter

Model NO.
ISODA
Customized
Customized
Dimension
83*37*51
Input
RS232/RS485 Digital Signal
Output Signal
0-20mA|4-20mA|0-5V|0-10V|0-75mv, etc
Power Supply
8-50VDC
Acquisition Bit
24-Bit
Accuracy
Better Than 0.2%
Installation
35mm DIN Rail-Mounted Type
Protocol
Modbus RTU
Operating Temperature
-45-+85 Cel. Degree.
Trademark
YUAN
Transport Package
DIN35
Specification
CE, RoHS, ISO9001: 2008
Origin
Shenzhen China
HS Code
9026900000
Model NO.
ISODA
Customized
Customized
Dimension
83*37*51
Input
RS232/RS485 Digital Signal
Output Signal
0-20mA|4-20mA|0-5V|0-10V|0-75mv, etc
Power Supply
8-50VDC
Acquisition Bit
24-Bit
Accuracy
Better Than 0.2%
Installation
35mm DIN Rail-Mounted Type
Protocol
Modbus RTU
Operating Temperature
-45-+85 Cel. Degree.
Trademark
YUAN
Transport Package
DIN35
Specification
CE, RoHS, ISO9001: 2008
Origin
Shenzhen China
HS Code
9026900000
RS232/485 Digital to Analog Signal (D-A) Converter with MODBUS RTU

>>RS232/RS485 A-D Converter General Parameters:
(typical @ +25, Vs: 24VDC)
Outputs: Voltage / Current
Accuracy: 0.2%
Output imbalance: Current output ± 0.5 uA/, voltage output ± 0.1 mV/.
Temperature Drift: ± 20 ppm/ (± 30 ppm/, max)
Output load: Current output 350Ω (4-20mA/0-20mA/0-± 20mA)
Voltage output 10mA(0-5V/0-10V/0-± 5V)
Communications: Support the standard Modbus RTU protocol and ASCII character
Communication protocol, RS-485 or RS-232 interface.
Baud rate(300 BPS, 600 BPS, 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS,
38400BPS) software selectable, address(00H~FFH)software selectable
Response Time: 100 ms max
Operation Power Supply: +8 ~ 50 VDC wide power supply range, internal anti-reverse
& over-voltage protection.
Watt consumption: < 1.5W
Operation Temperature: - 45 ~ +80
Operation Humidity: 10 ~ 90% (non-condensing)
Storage Temperature: - 45 ~ +80
Storage Humidity: 10 ~ 95% (non-condensing)
Isolation withstand voltage: Between interface and output: 3KVDC, one minute, stray current: 1mA.
Interface and power supply are common-ground
Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)
Weight: About 72g

>>RS232/RS485 A-D Converter Model Selection:
ISODA O-
Out voltage or current value---O

O1: 4-20mA 485: Out is RS-485 interface
O2: 0-20mA 232: Out is RS-232 interface
O4: 0-5V 232/485: Out is one RS232 or RS485 interface
O5: 0-10V (Key-press Choice)
O6: 1-5V
O7: 0-± 5V
O8: User-defined
O9: 0-± 20mA

Communication Interface:
485: Out is RS-485 interface
232: Out is RS-232 interface
232/485: Out is one RS232 or RS485 interface (key-press choice)

Note: For more detials regarding RS232/485 Digital to Analog Signal (D-A) Converter with MODBUS RTU, please contact SUNYUAN Technology.