China RS485 AC Current Integrator Instrument Transformer Waterproof IP66 Signal Conditioner S9.42, Find details about China Integrator Rogowski Coil Signal Conditioner, 4-20mA Flexible Sensor Rogowski Integrator from RS485 AC Current Integrator Instrument Transformer Waterproof IP66 Signal Conditioner S9.42
Model | S9.42 | |
Output | RS485 interface | |
Amplitude accuracy | ±0.5% rdg.±0.2%f.s. (45Hz~66Hz, Coil vertical center position) | |
Linearity | ±0.2% (10%~100% F.S.) | |
Bandwidth | 30Hz~5kHz | |
Temperature drift | 50ppm/ºC | |
Weight | ≤150g | |
Size | 114mm*42mm*29mm | |
Material | PC | |
Power supply | 5VDC,12VDC,24VDC | |
Power consumption | ≤0.5W | |
Working temperature | -20ºC~70ºC | |
Storage temperature | -30ºC~90ºC | |
Relative humidity | Maximum 80%, no condensation | |
Protection level | IP66 | |
Wiring definition | Red | Power + |
Blue | Power - | |
Green | RS485 port A | |
Yellow | RS485 port B | |
For other requirements, please contact us for customization |
Parameter | Effective value | Default value |
Baud rate | -1200 -2400 -4800 -9600 -19200 | 9600 |
Parity check | - Odd - Even -None | None |
Data bits | 8 | 8 |
Stop bit | 1 | 1 |
Address | 1-247 | 1 |
Slave address | Function code | Command data | CRC check |
8-Bits | 8-Bits | N×8-Bits | 16-Bits |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. | Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) | ||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) | Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% | |
Code:SRC | Code:50 Code:100 Code:150 | Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | |
Other requirement could be OEM |
Integrator | Output form | Output value | Rated current | Power supply |
Code:D1 (DIN-RAIL integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -5(5V) | Code: -600A Code: -1kA Code: -3kA Code: -6kA | Code: -12(12V DC) Code: -24(24V DC) |
Code: .3(4-20mA output) | N/A | |||
Code:S9 (mini integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -3(3V) | Code: -12(6-12V DC) Code: -24(24V DC) | |
Code:S1 (high accuracy integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -5(5V) Code: -10(10V) | Code: -12(4-12V DC) Code: -24(24V DC) | |
Code: .3(4-20mA output) | N/A | |||
Code:ATP-01 (1A output three phase integrator) | N/A(0-1A) | N/A | Code: -12(12V DC) Code: -24(24V DC) | |
Code:A01 (1A output integrator) | N/A(0-1A) | N/A | N/A(85-265V AC DC) | |
Code:A05 (5A output integrator) | N/A(0-5A) | N/A | N/A(85-265V AC DC) | |
Code:HF (high frequency integrator) | N/A(0-10VAC peak) | N/A | Code: -1kA(1kA/1V) Code: -10kA(10kA/1V) | N/A(4-12V DC) |
Other requirement could be OEM |