Lab Temperature Chamber Test for battery Cell

China Lab Temperature Chamber Test for battery Cell, Find details about China Universal Testing Machine, Test Equipment from Lab Temperature Chamber Test for battery Cell

Model NO.
BTL-D2-SERIES
Weight
0-100Kg
Power Source
AC 380V 50Hz
Structure Mode
an Integral Structure with Upper and Lower Cabinet
Temperature Range
-40ºC — +150ºC
Temperature Fluctuation
±0.3ºC
Heating Rate
Average 1~3°c/Minute (Non-Linear No-Load)
Cooling Rate
Average 1.0°c/Min Full Rang
Temperature Uniformity
≤±2ºC(at No Load, Constant State)
Observation Window
Three-Layer Vacuum Tempered Glass
Cooling Mode
Air Cooling / Water Cooling (Optional)
Compressor
Tecumseh (France)
Trademark
DGBELL
Transport Package
Each Set Protected with Resin Fiber and PP Film, T
Specification
Test Space 600x850x800(customizable)
Origin
Guangdong China
HS Code
8514109000
Model NO.
BTL-D2-SERIES
Weight
0-100Kg
Power Source
AC 380V 50Hz
Structure Mode
an Integral Structure with Upper and Lower Cabinet
Temperature Range
-40ºC — +150ºC
Temperature Fluctuation
±0.3ºC
Heating Rate
Average 1~3°c/Minute (Non-Linear No-Load)
Cooling Rate
Average 1.0°c/Min Full Rang
Temperature Uniformity
≤±2ºC(at No Load, Constant State)
Observation Window
Three-Layer Vacuum Tempered Glass
Cooling Mode
Air Cooling / Water Cooling (Optional)
Compressor
Tecumseh (France)
Trademark
DGBELL
Transport Package
Each Set Protected with Resin Fiber and PP Film, T
Specification
Test Space 600x850x800(customizable)
Origin
Guangdong China
HS Code
8514109000

Lab temperature chamber test for battey cell


Features:

1. Professional explosion-proof pressure relief design.

2. Professional high temperature smoke exhaust design.

3. Rich temperature monitoring and alarm mode.

4. Insulated and heat-resistant inner wall and partition.

5. Water-based and gas fire extinguishing firefighting linkage experience.

6. Design and guidance of sample layout and wiring.

7. Spray cooling water supply and drainage design.

8. Long-term operation of energy saving and consumption reduction design.

9. Consideration of integration with charging and discharging modules.

10. Better temperature uniformity.

11. Consistent low wind speed conditions.
Lab Temperature Chamber Test for battery Cell

Application

Double-deck High Low Temperature Test Chamber provides a constant high and low temperature environment condition ranges from -40°C to 150°C (Available for customized design). It is widely used to test the thermal performance of various products and components. The two test cabinets work independently, providing high efficiency and performance for laboratory testing. Furthermore, the additional explosion-proof function enables this test chamber to be combined with the charge-discharge test, providing a temperature environment for various battery performance testing.

 

Features

  1. PLC Control, programmable, remote computer control
  2. Heating System
  3. Refrigeration System
  4. Forced Internal Circulate System
  5. Fume Exhaust System
  6. Explosion-proof System

 

Standards

  • IEC 60068-2-1:2007: Low temperature testing
  • IEC 60068-2-2:2007: High temperature testing
  • GJB 150.3-1986: High temperature testing
  • GJB 150.4-1986: Low temperature testing
  • GB/T 2423.1-2008: Low temperature testing
  • GB/T 2423.2-2008: High temperature testing
  • GB/T 31485-2015: Safety requirements and test methods for electric vehicles' power batteries

 

Performance parameters
ModelBTL-D2-252BTL-D2-288BTL-D2-360
Single Cabinet Inner DimensionW600 X D700 X H600 MMW800 X D600 X H600 MMW1000 X D600 X H600 MM
External DimensionW1300 X D1800 X H1950 MMW1500*H1950*D1700 MMW1740*H1900*D2100 MM
Structure ModeAn integral structure with upper and lower cabinets.
Temperature Range-40ºC - +150ºC
Temperature Fluctuation±0.3ºC
Heating RateAverage 1~3°C/minute (non-linear no-load)
Cooling RateAverage 1.0°C/min Full rang (non-linear no-load)
Temperature Uniformity≤±2ºC(at no load, constant state)
Observation WindowThree-layer vacuum tempered glass
Test Terminal12 sets of terminals are connected to the test cabinet inside and outside of the chamber
Cooling ModeAir cooling / Water cooling (Optional)
CompressorTecumseh (France)
Controlling ModeTouch screen programmable control PLC, with USB interface, with RS485 .interface can be connected to computer control, special network control software, convenient remote monitoring, data acquisition
Internal Chamber Material1.0MM thick SUS304# stainless steel with mirror finish, sprayed with Teflon insulation
External Chamber Material1.2 MM thick Galvanized sheet, dusting pained with high temperature plasticized coating.
Power SupplyAC380V 50HZ   12KW/14KW/16KW
Safety ProtectionAutomatic explosion-proof pressure relief device, explosion-proof chain, tri-color light alarm device, remote control, smoke exhaust device, fire extinguishing device, etc.
Extension FunctionProvide communication protocol, able to accompanied use with charge and discharge machine


Use common sense of high and low temperature test chamber

  1. The enclosure of the high and the low test chamber must be grounded during installation. If the high and low temperature test chamber is not grounded, there will be a risk of electric shock in case of leakage.
  2. Do not run the high and low temperature test chamber before it is installed, and make sure that the installation is reliable before performing the test.
  3. If heating samples are placed in the test chamber, please use an external power supply for the sample control power supply, do not use the power supply of this test chamber directly.
  4. The operation of the cabinet will produce a dangerous current, non-professionals should not open the cover of the electric control cabinet.
  5. If the high and low temperature test chamber is not equipped with humidification function, pay attention to the difference in use and requirements when reading the instructions.
  6. When the test chamber is running, various motors and fans are started according to instructions under the control of the controller. Do not touch the components that are temporarily in a static state with your hands to prevent the components from starting suddenly and causing personal injury. It is indeed necessary to approach the rotating parts, please cut off the main power switch and ensure that the protective device is in good condition when working at the place.
  7. It is forbidden to move the test chamber when there is a sample inside, otherwise, the sample may reverse or fall.
  8. Before use, make sure that the high and low temperature test chamber is fixed, the casters are off the ground to adjust the foot to the ground, otherwise, the test chamber will accidentally move when subjected to the external force.
Lab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery Cell

Established in 2005, Guangdong Bell Experiment Equipment Co., Ltd is specialized in manufacturing a variety of quality inspection instruments, testing equipments and other high-tech products which mainly include: ,High & Low Temperature Test Chamber, High & low Temperature Testers with Rapid Temperature Change, , Cool/Thermal shock test chamber, , , sand and dust testing machine,tension tester, high and low temperature testing machine , servo computer battery crush tester, mechanical vibration testerBattery washing tester ,battery burning tester and other quality testing instruments. Thanks to several decades of R&D efforts,the company has established itself as a leading provider of testing instruments of the industry, playing a crucial role in the research and development of high-quality and high-value products within the industry.

15+ years experience in test chambers manufacturing, High performance for your projects.

With unmatched quality advantage, a dynamic management team, professional customer services, superb manufacturing techniques and innovative research and development ideas, Guangdong Bell Experiment Equipment Co., Ltd, supported by an international, standard and professional quality policy, is gradually becoming an international brand. Its products are manufactured in consistent with a number of world standards.


Lab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellLab Temperature Chamber Test for battery CellFAQ

Q1 : Can you customize the product?
   A:  Yes, we can customize any products according to requirements. Hot selling lab electronic
        temperature humidity cabinet/Environmental climate test chamber/Car Battery Safety Test Chamber also can            be customized.
 
Q2 : How to choose the most suitable products?
    A: Our professional team will give you the best suggestion, just be patiently to tell us the information
       about the parameters you require.

Q3 : Can you arrange installations and commissioning in our lab?
   A:  Firstly, for standard chamber we had 3-5 days commissioning before shipping,
         you just need link power in your lab, then you can start to operate.
        Secondly, we had detailed operation manual with chamber , any problems you can find and solve in it.
        Thirdly, some customized chambers we should install and teach your team to operate .
 
How to Contact Us?

Please send your inquiry details below or send them to my mail below. We promise to reply to your inquiry on time.