China Medical Equioment Vital Signs Patient Monitor with Touch Screen, Find details about China Touch Screen Vital Sign Patient Monitor, Patient Monitor from Medical Equioment Vital Signs Patient Monitor with Touch Screen
Introduction
This Vital Signs Patient Monitor can mueasure parameters: ECG, RESP, SpO2, PR, NIBP and TEMP, etc.
This medical equipment is a portable monitor with touch screen. To ensure monitoring quality and reduce operation risk, it adopts full-isolation(floating), ECG defibrillation-proof protection, ECG anti-high frequency interference and NIBP dual-overpressure protection technique, which is applicable for monitoring adult, pediatric and neonate.
Features
Performance | ||
ECG | Lead mode | 3-lead or 5-lead |
Lead selection | I, II, III, aVR, aVL, aVF, V | |
Waveform | 5-lead, 2-channel3-lead, 1-channel | |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV | |
Scan speed | 12.5mm/s, 25 mm/s, 50 mm/s | |
HR | Measurement and alarm range | 15~350bpm |
Accuracy | ±1% or ±1bpm, whichever is greater | |
Alarm accuracy | ± 2 bpm | |
Resolution | 1 bpm | |
Measurement and alarm range | -2.0mV~+2.0mV | |
Accuracy | 0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greater | |
Arrhythmia analysis | ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC | |
Other range | unspecified | |
Pacemaker | yes | |
RESP | Method | R-F(RA-LL) Impedance |
Measurement and alarm range | 0~150 rpm | |
Resolution | 1 rpm | |
Measurement accuracy | ±2 rpm | |
Alarm accuracy | ±3 rpm | |
Apnea alarm | 10~40s | |
Scan speed | 12.5 mm/s, 25 mm | |
NIBP | Method | Oscillometry |
Mode | Manual/AUTO/STAT | |
Measurement interval in AUTO mode | 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes | |
Measurement period in Continuous mode | 5 minutes | |
Measurement and alarm range | 10 ~ 270 mmHg | |
Resolution | 1 mmHg | |
Cuff pressure accuracy | ±3 mmHg | |
Maximal mean deviation | ±5 mmHg | |
Maximal standard deviation | 8mmHg | |
Adult mode | 297±3 mmHg | |
Pediatric mode | 240±3 mmHg | |
Neonatal mode | 147±3 mmHg | |
SpO2 | Measurement and alarm range | 0 ~ 100% |
Resolution | 1% | |
Measurement accuracy | 70%~100%: ±2% 0%~69%: unspecified | |
PR | Measurement and alarm range | 30 ~ 250 bpm |
Measurement accuracy | ±2 bpm or ±2%, whichever is greater | |
TEMP | Channel | dual-channel |
Measurement and alarm range | 0 ~ 50ºC | |
Resolution | 0.1 ºC | |
Accuracy | ±0.1 ºC | |
AC | 100 ~ 240 (V), 50/60 (Hz) | |
Safety classification | Class I, type CF defibrillation-proof applied part | |
Adapter | 9 (V) DC | |
Maximal input power | 150VA |
Physical characteristic
Dimension: 192x162x243(mm)(L×W×H)
Weight: 2.0kg
Accessories
Certification
CE
-TELEMEDICINE products
-Pulse oximeter