China Weak-Current Kabel Jc2xfe-R 10X2X1.3mm2 Cu/XLPE/OS/Lsoh Instrumentation Cable, Find details about China Instrumentation Cable, Instrument Cable from Weak-Current Kabel Jc2xfe-R 10X2X1.3mm2 Cu/XLPE/OS/Lsoh Instrumentation Cable
The cables can be used for signal transmission in measuring, control and safety circuits where is insisted on personal protection, on the protection of equipments, constructions and of materials (e.g. in public spaces, shopping malls, in hospitals, hotels or in tunnel constructions). It is possible to use them in dry or wet environment.
Electrostatic screening ensures the protection against electrical interference.
The cables can be placed in the environment with the explosion danger (zone 1, 2) providing compliances with the conditions of intrinsic safety according to IEC 60079-11.
JCXFE-R
Weak-current cable - screened, fire retardant, halogen-free
Construction:
1. Conductor Cu conductor of the category 1 according to IEC 60228
2. Insulation XLPE
3. Cable core cores are twisted in pairs, pairs are laid up into cable core
4. Bedding none
5. Screening wrapping by Al/PET foil + CuSn drain wire
6. Sheath fire retardant halogen-free polymer compound
Rated voltage: 500 V AC
Testing voltage between cores: 2000 V
Testing voltage between core and screening: 750 V
Insulation resistance: > 1000 MΩ.km
Surrounding temperatures (fixed placement): - 40°C up to + 90°C
Surrounding temperatures (during installation): -5°C up to +50°C
Minimum bending radius (fixed placement): 10D
RE-2X(St)H PiMF | ||||
No. of Pairs x2xCross Section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
No.x2xmm2 | mm | mm | mm | kg/km |
0.5mm2, Multipair | ||||
2x2x0.5 | 0.35 | 0.9 | 8.7 | 85 |
4x2x0.5 | 0.35 | 1.0 | 10.2 | 120 |
5x2x0.5 | 0.35 | 1.0 | 11.2 | 145 |
6x2x0.5 | 0.35 | 1.0 | 12.1 | 170 |
8x2x0.5 | 0.35 | 1.1 | 13.1 | 214 |
10x2x0.5 | 0.35 | 1.2 | 15.1 | 265 |
12x2x0.5 | 0.35 | 1.2 | 15.7 | 286 |
16x2x0.5 | 0.35 | 1.2 | 17.8 | 380 |
20x2x0.5 | 0.35 | 1.3 | 19.7 | 475 |
24x2x0.5 | 0.35 | 1.4 | 21.5 | 561 |
0.75mm2, Multipair | ||||
2x2x0.75 | 0.38 | 1.0 | 9.7 | 101 |
3x2x0.75 | 0.38 | 1.0 | 11.2 | 159 |
4x2x0.75 | 0.38 | 1.1 | 12.5 | 183 |
5x2x0.75 | 0.38 | 1.1 | 13.6 | 215 |
8x2x0.75 | 0.38 | 1.1 | 14.4 | 272 |
10x2x0.75 | 0.38 | 1.2 | 16.6 | 333 |
12x2x0.75 | 0.38 | 1.2 | 17.4 | 383 |
16x2x0.75 | 0.38 | 1.3 | 19.8 | 492 |
20x2x0.75 | 0.38 | 1.4 | 22.0 | 603 |
24x2x0.75 | 0.38 | 1.5 | 24.0 | 704 |
1.0mm2, Multipair | ||||
2x2x1.0 | 0.4 | 1.0 | 10.4 | 112 |
3x2x1.0 | 0.4 | 1.0 | 12.1 | 179 |
4x2x1.0 | 0.4 | 1.1 | 13.5 | 220 |
5x2x1.0 | 0.4 | 1.1 | 14.7 | 256 |
8x2x1.0 | 0.4 | 1.2 | 15.8 | 323 |
10x2x1.0 | 0.4 | 1.2 | 18.0 | 401 |
12x2x1.0 | 0.4 | 1.3 | 19.0 | 454 |
16x2x1.0 | 0.4 | 1.3 | 21.5 | 601 |
20x2x1.0 | 0.4 | 1.4 | 23.9 | 719 |
24x2x1.0 | 0.4 | 1.5 | 26.1 | 884 |
1.3mm2, Multipair | ||||
2x2x1.3 | 0.45 | 1.0 | 11.4 | 153 |
3x2x1.3 | 0.45 | 1.1 | 13.4 | 208 |
4x2x1.3 | 0.45 | 1.1 | 14.8 | 263 |
5x2x1.3 | 0.45 | 1.2 | 16.3 | 318 |
8x2x1.3 | 0.45 | 1.3 | 17.6 | 406 |
10x2x1.3 | 0.45 | 1.3 | 20.0 | 501 |
12x2x1.3 | 0.45 | 1.4 | 21.1 | 552 |
16x2x1.3 | 0.45 | 1.5 | 24.1 | 728 |
20x2x1.3 | 0.45 | 1.6 | 26.8 | 892 |
24x2x1.3 | 0.45 | 1.7 | 29.2 | 1067 |
1.5mm2, Multipair | ||||
2x2x1.5 | 0.45 | 1.0 | 11.8 | 164 |
3x2x1.5 | 0.45 | 1.1 | 13.9 | 235 |
4x2x1.5 | 0.45 | 1.2 | 15.5 | 289 |
5x2x1.5 | 0.45 | 1.2 | 16.9 | 366 |
8x2x1.5 | 0.45 | 1.3 | 18.2 | 446 |
10x2x1.5 | 0.45 | 1.4 | 21.0 | 565 |
12x2x1.5 | 0.45 | 1.4 | 21.9 | 637 |
16x2x1.5 | 0.45 | 1.5 | 25.1 | 828 |
20x2x1.5 | 0.45 | 1.6 | 27.8 | 1024 |
24x2x1.5 | 0.45 | 1.7 | 30.4 | 1219 |
Note : Other conductor sizes & core configurations are available upon request