Power Range: 10VA to 3000 VA
Size Range: EI-28 to EI-192
Phase: Single or 3Phase
Input/Output: Customized
Insulation: Primary to secondary 2.5kV, 1min, some parts up to 4kV, it desponds to the safety agency requirements.
Primary to safety ground 2.5kV, 1min
Secondary to safety ground 1.5kV, 1min
EI Transformer Sepecification | |||||||
VA | Regulation | Temp. Rise | Core | Dimension(mm) | |||
(Size) | (%) | (deg C) | (Size) | L | W | H | F/A×B |
12 | 18 | 60 | EI 48-18 | 50 | 34 | 44 | 61 |
15 | 18 | 60 | EI 48-20 | 50 | 36 | 44 | 61 |
18 | 18 | 60 | EI 48-24 | 50 | 40 | 44 | 61 |
20 | 18 | 60 | EI 48-30 | 50 | 46 | 44 | 61 |
25 | 16 | 60 | EI 57-20 | 59.5 | 44 | 50.5 | 70.5 |
30 | 15 | 60 | EI 57-24.5 | 59.5 | 48.5 | 50.5 | 70.5 |
35 | 13 | 60 | EI 57-30 | 59.5 | 54 | 50.5 | 70.5 |
40 | 12 | 60 | EI 57-35 | 59.5 | 59 | 50.5 | 70.5 |
44 | 12 | 60 | EI 66-24 | 68.5 | 52 | 58.5 | 81.5 |
55 | 11 | 60 | EI 66-30 | 68.5 | 58 | 58.5 | 81.5 |
60 | 10 | 60 | EI 66-36 | 68.5 | 64 | 58.5 | 81.5 |
65 | 9 | 60 | EI 66-40 | 68.5 | 68 | 58.5 | 81.5 |
70 | 8.5 | 60 | EI 66-45 | 68.5 | 71 | 58.5 | 81.5 |
80 | 8 | 60 | EI 76-32 | 78.5 | 62 | 68.5 | 90 |
100 | 8 | 60 | EI 76-38 | 78.5 | 68 | 68.5 | 90 |
120 | 7.8 | 60 | EI 76-45 | 78.5 | 75 | 68.5 | 90 |
135 | 7.5 | 60 | EI 76-50 | 78.5 | 80 | 68.5 | 90 |
140 | 7.5 | 60 | EI 86-38 | 86.2 | 72 | 72 | 71×63 |
145 | 7 | 60 | EI 86-42 | 86.2 | 76 | 72 | 71×67 |
155 | 6.8 | 60 | EI 86-45 | 86.2 | 79 | 72 | 71×70 |
175 | 6.5 | 60 | EI 86-50 | 86.2 | 84 | 72 | 71×75 |
155 (1) | 6.5 | 60 | EI 96-32 | 96 | 69 | 80.5 | 76×55 |
180 | 6.5 | 60 | EI 96-38 | 96 | 75 | 80.5 | 76×61 |
210 | 6.4 | 60 | EI 96-45 | 96 | 82 | 80.5 | 76×68 |
230 | 6.4 | 60 | EI 96-50 | 96 | 87 | 80.5 | 76×73 |
265 | 6.4 | 60 | EI 96-60 | 96 | 97 | 80.5 | 76×83 |
210 (1) | 5 | 65 | EI 105-34 | 105 | 73 | 91 | 76×52 |
255 | 5 | 65 | EI 105-40 | 105 | 79 | 91 | 76×58 |
285 | 4.8 | 65 | EI 105-50 | 105 | 89 | 91 | 76×68 |
320 | 4.8 | 65 | EI 105-55 | 105 | 94 | 91 | 76×73 |
240 | 4.6 | 65 | EI 105-60 | 105 | 99 | 91 | 76×78 |
375 | 4.6 | 65 | EI 105-65 | 105 | 104 | 91 | 76×81 |
360 | 4.6 | 65 | EI 114-45 | 114 | 89 | 97.5 | 95×75 |
400 | 4.6 | 65 | EI 114-50 | 114 | 94 | 97.5 | 95×80 |
440 | 4.5 | 65 | EI 114-55 | 114 | 99 | 97.5 | 95×85 |
480 | 4.5 | 65 | EI 114-60 | 114 | 104 | 97.5 | 95×90 |
520 | 4.5 | 65 | EI 114-65 | 114 | 109 | 97.5 | 95×95 |
530 | 4.4 | 70 | EI 133-50 | 136 | 115 | 114 | 125×86 |
580 | 4.4 | 70 | EI 133-55 | 136 | 128 | 114 | 125×91 |
630 | 4.4 | 70 | EI 133-60 | 136 | 125 | 144 | 125×96 |
680 | 4.3 | 70 | EI 133-65 | 136 | 129 | 144 | 125×101 |
730 | 4.3 | 70 | EI 133-70 | 136 | 135 | 144 | 125×106 |
780 | 4.3 | 70 | EI 133-75 | 136 | 141 | 144 | 125×111 |
830 | 4.2 | 70 | EI 133-80 | 136 | 144 | 144 | 125×116 |
870 | 4.2 | 70 | EI 133-85 | 136 | 151 | 144 | 125×122 |
925 | 4.2 | 70 | EI 133-90 | 136 | 154 | 144 | 125×127 |
975 | 4.2 | 70 | EI 133-95 | 136 | 159 | 144 | 125×132 |
1025 | 4.2 | 70 | EI 133-100 | 136 | 164 | 144 | 125×137 |
Toroidal Transformer Main Materials (IQC process)
All the material is inspected strictly with ISO9001:2008 quality program.
EI lamination: appearance inspection and core loss test.
Copper wire: pinhole test and coat of adhesion testEI Transformer Testing Items
Transformer applications