New Vital Signs Patient Monitor / NIBP Patient Monitor

China New Vital Signs Patient Monitor / NIBP Patient Monitor, Find details about China Patient Monitor, Medical Equipment from New Vital Signs Patient Monitor / NIBP Patient Monitor

Model NO.
AJ-3400/AJ-3400A/A-3400B/AJ-3400C
Trademark
ANJUE
Specification
ISO; CE
Origin
China
Model NO.
AJ-3400/AJ-3400A/A-3400B/AJ-3400C
Trademark
ANJUE
Specification
ISO; CE
Origin
China
Vital Signs Patient Monitor / NIBP Patient Monitor

NIBP+SpO2+TEMP+PR (4 Parameters) Vital Signs Patient Monitor AJ-3400
NIBP+SpO2+PR (3 Parameters) Vital Signs Patient Monitor AJ-3400A
SpO2+TEMP+PR (3 Parameters) Vital Signs Patient Monitor AJ-3400B
NIBP+PR (2 Parameters) Vital Signs Patient Monitor AJ-3400C

Features
Four parameters: NIBP, SpO2, Pulse Rate, Temperature
* SpO2 waveform, PR strength display
* 2.8 inch color LCD with real time display
* Storage/Review trend data up to 3888 groups, data save time interval settable
* Audio and visual alarm when parameters exceeded and sensor-off
* Built-in rechargeable Li-ion battery, up to 4 hour running time
* Automatic shutdown for power saving, shutdown time interval settable
* Via USB to connect with the computer, unique software for telemonitoring By transmitting data synchronously via internet
* Battery capacity indicatior and prompt when battery low


Technical Specifications
*NIBP
Measure Method: Automatic oscillometric
Patient: Adult and Pediatric
Measurement unite: MmHg/kPa selectable
Measurement mode: Manual, Auto, STAT
Measurement Type: SYS, DIA, MAP
Measurement interval in AUTO mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60Min
Measuring period in STAT mode: 5 Min

Measure range:
Adult: 30~2550 mmHg; Child: 30~160 mmHg
Accuracy: 1 mmHg
Alarm limits range:
SYS: Upper limits70~250 mmHg, Lower limits 60~180 mmHg
DIA: Upper limits 40~200 mmHg, Lower limits35~150 mmHg
MAP: Upper limits 60~230 mmHg, Lower limits 50~160 mmHg

*SpO2
Measure Range: 35~100%
SpO2 Accuracy: 2%(70~99%), 3%(40~70%)
Pulse Rate Range: 0~254 bpm
Pulse Rate Accuracy: 1 bpm
*Alarm limits range:
SpO2 upper limits: 95~100% lower limits: 85~96%
Pulse Rate: Keep up with the heart rate

*Temperature
Channel: 1
Input: Body surface thermal-sensitive resistor temperature sensor
Measurement Unit: C/° F selectable
Measure range: 0~50ºC
Alarm limits range: Upper limits 36~45ºC Lower limits 34~38ºC
Measure accuracy: ºC 0.1

*System Specifications
Alarm ON/OFF: Controlled by general switch and parameter switch (two levels)
Display mode: LED and 2.8' color LCD screen
Trend data: 3888 groups of SpO2, TEMP, SYS, DIA trend data, The record time interval can be set to 5 Sec. To 120 Sec., so that the record time rang can be up to 128 hr.
AC power adaptor
Input: AC 100~240V, 50/60Hz, 0.7A
Output: DC 5V, 2.5A

Internal battery
Type: 2800mAh/3.7V Li-ion rechargeable battery
Operating Time: 6 hours of stand-by time with a full battery.
Recharge time: 8 hours
Dimension: 280mm× 190mm× 100mm
Net Weight: 1000g