China 165kw Wuxi Power Diesel Generator Sets Electric Generator for Sales, Find details about China Diesel Generator, Silent Generator from 165kw Wuxi Power Diesel Generator Sets Electric Generator for Sales
165KW Wuxi Diesel Generator Set Data | ||
Manufacturer: | Jiangsu Starlight Electricity Equipment Co.,Ltd | |
Set Type: | XG-165GF | |
Prime Power: | 165KW / 206.25KVA | |
Rated Current: | 270(A) | |
Rated Frequency: | 50(Hz) | |
Start-up time: | 5~6(s) | |
Power Factor: | 0.8 (Low) | |
Rated Voltage: | 400/230 (V) | |
Standard Features | ||
| |
Diesel Engine Data | |
Manufacturer: | WUXI Engine |
Model: | WD129D16 |
Standby/Prime Power: | 178KW/161.8KW |
Rated Speed: | 1500(r/min) |
Cycle: | 4 stroke |
Cylinder Arrangement: | 6 in line |
Displacement: | 12.9 L |
Bore and Stroke: | 135*150(mm) |
Compression Ratio: | 1 7 : 1 |
Governor Type: | Mechanical |
Start battery voltage: | 24V DC |
Air Intake System | |
Air Intake System: | Turbo, Air/Air Cooling |
Max Intake Restriction: | 6.35kp a |
Burning Capacity: | 16.4 m3 / min |
Air Flow: | 248 m3 / min |
Exhaust System | |
Exhaust Gas Flow: | 42.9 m3 / min |
Exhaust Temperature: | 610ºC |
Max Back Pressure: | 10 kPa |
Fuel System | |
Fuel System: | Pressure lubrication |
100%( Prime Power) Load: | 213g/kwh |
50%( Prime Power) Load: | 228g/kwh |
Oil System | |
Total Oil Capacity: | 28 L |
Oil Consumption: | ≤ 0.4g / kwh |
Engine Oil Tank Capacity: | 23 L |
Oil Pressure at Rated RPM: | 345-483 kPa |
Cooling System | ||||||||
Cooling Way: | Water-cooled | |||||||
Total Coolant Capacity: | 36L | |||||||
Thermostat: | 83-95ºC | |||||||
Max Water Temperature: | 1 03ºC | |||||||
Alternator Data | ||||||||
Manufacturer: | STARLIGHT / STAMFORD / SIEMENS / MARATHON / ENGGA / KEPU | |||||||
Excitation Mode: | Brushless and self- exciting | |||||||
Number of phase and Access Act: | 3-phase 4-wire | |||||||
Connecting Type: | "Y" type connecting | |||||||
Alternator Capacity: | 187.5 KVA | |||||||
Alternator Efficiencies: | 95 % | |||||||
Overload: | (PRP)110% load can run 1h | |||||||
Protection Level: | IP22-IP23 | |||||||
Insulation Class, Temperature Rise: | H / H | |||||||
Telephone Influence Factor (TIF): | < 50 | |||||||
THF: | < 2% | |||||||
Voltage Regulation, Steady State: | ≤ ± 1% | |||||||
Air Cooling Flow: | 0.8m3/s | |||||||
Altitude: | ≤1000m | |||||||
Genset Electrical Performance | ||||||||
Voltage Regulation: | ≥ ± 5% | |||||||
Voltage Regulation, Stead State: | ≤ ± 1% | |||||||
Sudden Voltage Warp (100% Sudden Reduce): | ≤ + 25% | |||||||
Sudden Voltage Warp (Sudden Increase): | ≤-20% | |||||||
Voltage Stable Time (100% Sudden Reduce): | ≤6S | |||||||
Voltage Stable Time (Sudden Increase): | ≤6S | |||||||
Frequency Regulation, Stead State: | ≤5% | |||||||
Frequency Waving: | ≤1.5% | |||||||
Sudden Frequency Warp (100% SuddenReduce): | ≤ + 12% | |||||||
Sudden Frequency Warp (Sudden Increase): | ≤-10% | |||||||
FrequencyRecoveryTime(100%SuddenReduce): | ≤5S | |||||||
FrequencyRecoveryTime(Sudden Increase): | ≤5S | |||||||
Options | ||||||||
Engine | Alternator | |||||||
Heater 2KW & 4KW | Anti Condensation Heater | |||||||
Battery Charger 3.5A & 7A | Permanent Magnet Generator(PMG) | |||||||
Water Separator | Drop CT(For Paralleling) | |||||||
Daily Fuel Tank | ||||||||
Fuel Level Sensor | ||||||||
Control System | Others | |||||||
Remote Control Panel | Rainproof Type | |||||||
Auto Transfer Switch (ATS) | Soundproof Type | |||||||
Paralleling System | Trailer Type |