Solar Panel DC to Three Phase AC Solar Water Pump Inverter Made in China Hot Sale, Find details about China AC Drive, Frequnce Converters from Solar Panel DC to Three Phase AC Solar Water Pump Inverter Made in China Hot Sale
Identification | Voltage level |
4 | three-phase 380V |
S2 | Single-phase 220V |
Identification | Adaptive motor type |
G | General type |
Identification | 0.4 | 0.75 | ... | 400 |
Adaptive motor(KW) | 0.4 | 0.75 | ... | 400 |
Item | Specification | |
Standard functions | Control mode of Motor 1 | 0: No-speed sensor vector control (SVC); 2: V/F control |
Maximum frequency | 50.00Hz ~ 500.00Hz | |
Carrier frequency | 0.5kHz ~ 16.0kHz The carrier frequency is automatically adjusted based on the load features. | |
Input frequency resolution | Digital setting: 0.01Hz; Analog setting: maximum frequency × 0.025% | |
Starting torque | 0.5Hz/150% | |
Basic functions | Speed range | 1:100 |
Constant-speed accuracy | ±1% | |
Overload capacity | 60s for 150% of the rated current | |
Torque boost | Automatic torque boost; 0.1%~30.0% | |
V/F curve | 0: Straight-line V/F curve 1: Multi-point V/F curve 2: Square V/F 3: 1.2th power V/F 4: 1.4th power V/F 6: 1.6th power V/F 8: 1.8th power V/F 3-8:VF relation curve between straight line VF and square VF 9: Reserved 10: VF complete separation mode 11: VF semi-separation mode | |
Acceleration / deceleration curve | Straight-line or S-curve acceleration and deceleration Four groups of acceleration/deceleration time with the | |
Voltage acceleration time of VF separation | 0.0s ~1000.0s | |
Note: The above means the time of variation from 0 V to the rated voltage of motor | ||
Voltage deceleration time of VF separation | 0.0s ~1000.0s | |
Note: The above means the time of variation from 0 V to the rated voltage of motor | ||
DC braking | DC braking frequency: 0.00Hz~maximum frequency | |
Braking time: 0.0s~36.0s | ||
Braking action current value: 0.0%-100.0% | ||
JOG control | JOG frequency range: 0.00Hz-maximum frequency | |
JOG acceleration/deceleration time: 0.0s-6500.0s | ||
Operation | Command source | 0: Command channel of operation panel (LED OFF) |
1: Command channel of the terminal (LED ON) | ||
2: Communication command channel (LED flashes) | ||
Selection of main frequency source X | 1: Digital setting (Preset frequency F0-08, changeable UP/DOWN, power-down memory) | |
2:AI1 | ||
3:AI2 | ||
4:AI3(key potentiometer) | ||
5: PULSE setting (DI5) | ||
6: Multi-stage instruction | ||
7: Simple PLC | ||
8:PID | ||
9: Communication reference | ||
Input terminal | Standard: 4 digital input terminals, 1 analog input terminal, support 0 ~ 10V voltage input or 4 ~ 20mA current input | |
Output terminal | Standard: 1 relay normally open output terminal, 1 analog output terminal, support 00 ~ 10V voltage output | |
Display and keyboard operation | LED display | Display the parameter |
Key lock and function selection | Realize partial or all key lock and define the action range of some keys to prevent misoperation | |
Protection function | Short circuit test of electrified motor, input/output default phase protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |