Clean Agent Fire Suppression Systems with FM200

China Clean Agent Fire Suppression Systems with FM200, Find details about China FM200 Clean Agent, Clean Agent Fire Suppression System from Clean Agent Fire Suppression Systems with FM200

Model NO.
ZF-120
Effective Range
5m
Retirement Life
10 Years
Dry Powder Type
Ordinary Dry Powder
Power Source
Pressure Fire Extinguisher
Color
Red
Fire Extinguishing Means
5.3MPa ~ 5.4MPa
Design Pressure of The Nozzle
Normal 0.7MPa, Min.0.40MPa
Working Temperature
-10 to +60
Discharging Time
Less 10s
Gas Filling Rate( Density)
Less 1.15kg/L
Power Supply
Dcv 24, 0.5A
Max Protected Area
Max 800m² , Max Volume 3600m³
Polit Valve Powder Supply
6.0± 1.0 MPa(20c)
System Working Pressure
-10c~55c
Trademark
Asenware
Transport Package
Carton
Specification
CE ISO9001
Origin
Shezhen China
HS Code
8531100000
Model NO.
ZF-120
Effective Range
5m
Retirement Life
10 Years
Dry Powder Type
Ordinary Dry Powder
Power Source
Pressure Fire Extinguisher
Color
Red
Fire Extinguishing Means
5.3MPa ~ 5.4MPa
Design Pressure of The Nozzle
Normal 0.7MPa, Min.0.40MPa
Working Temperature
-10 to +60
Discharging Time
Less 10s
Gas Filling Rate( Density)
Less 1.15kg/L
Power Supply
Dcv 24, 0.5A
Max Protected Area
Max 800m² , Max Volume 3600m³
Polit Valve Powder Supply
6.0± 1.0 MPa(20c)
System Working Pressure
-10c~55c
Trademark
Asenware
Transport Package
Carton
Specification
CE ISO9001
Origin
Shezhen China
HS Code
8531100000
Clean Agent Fire Suppression Systems with FM200
Clean Agent Fire Suppression Systems with FM200

HFC-227ea finds use in fire suppression systems in data processing and telecommunication facilities, and in protection of many flammable liquids and gases. HFC-227ea falls in the category of Clean Agents and is governed by NFPA 2001 - Standard for Clean Agent Fire Extinguishing Systems. Effective fire suppression requires introducing a concentration of the HFC-227ea agent between 6.25% and 9% depending on the hazard being protected. Its NOAEL level for cardiac sensitization is 9%. The United States Environmental Protection Agency allows concentration of 9% volume in occupied spaces without mandated egress time, or up to 10.5% for a limited time. Most fire suppression systems are designed to provide concentration of 6.25-9%.

FIRE DETECTS AND ALARMS
Fire control panel +smoke and heat detectors
Fire alarm bell +manual button,
Light warning gas discharging
Before we make offer we need follow technical,
Room size: Length width height
Protected subject
Better submit drawing of project
We can send offer within 24 hours after received your informations
 Working pressure 4.2 Mpa or 2.5Mpa
 
 Discharge time ≤ 10s
 
 Filling desity: ≤ 950kg/m3
 
 System working power: AC 220V DC 24V 1A
 
 System working pressure: 10c~55C
 
 Working method Manual, auto, and eletrical