Large Size Z, ZFQZ, Z4 DC Motor of Mill Auxiliary, Hoisting, Crane, Elevator, Excavator, Steel Mill, Plastic extruding machine DC Motor is newly developed products of our works.
The products are found wide use for prime mover in various, such as mill auxiliary in metallurgical industry, metal cutting machine-tool, paper making, print, textile, printing and dyeing, cement-making, plastic extruding machine, etc.
Features:
small size, good performance, light weight, large output, high efficiency and reliability
Outline and mounting dimensions of the motors comply with IEC72 Standard
Performance and technical requirements of the motors can be checked in accordance with IEC34-1 Standardor DIN57530 Norm of the Deutsche Industries-Norm.
Class F insulated, with reliable insulating construction and impregnating process, ensuring stable dielectric performance and excellent heat dissipation.
Performance:
Standard rated voltage: 160V/440V, 220V/400V, 380V/660V or other voltage as required
Rated speed: 3000, 1500, 1000, 750, 600, 500, 400, 300 and 200 r/min
Cooling method: IC06, IC17, IC37, IC86W
Protection: IP21S, IP23, IP44, IP54
Mounting: IMB3, IMB35, IMV1, IMV15
Duty: continuous S1
Ambient temperature: -15 ~ +40 Celsius degree
Altitude: within 1000m
The choice of the motors capacity
1.First kind (A): Ordinary industrial DC motor. The technical data of this kind of motor please see the technical data table. The buyer can decide the capacity, voltage, running speed and the method of cooling of the motor at the buyers option.
2. Second kind (B): Metal rolling mill DC motor. The output power of this kind of motor is about 20% lower than kind (A), the detail numerical value can be negotiated by the user and the manufacture.
3. Exclude the specification of technical data in the table. Manufacturer can derive other specification at the requirement of the user.
**** Part of Z4 series technical paremeter
Model | Rated power | Rated speed | Max. Speed | Arm. Current | Field power | Arm. Circuit Resistance | Arm Circuit Inductance | Field Inductance | Eff. |
PN | 160V | 400V | 440V | NF | IN | PF | R | LA | LF | LR |
kW | r/min | r/min | A | W | Ω(20°c) | mH | H | % |
Z4-112/4-1 | 10 | | 2680 | | 2500 | 29 | 500 | 0.89 | 9 | 6.8 | |
Z4-132-1 | 10 | | 1330 | | 2100 | 30.1 | 650 | 1.309 | 18.9 | 8.9 | 0.32 |
Z4-132-2 | 10 | | 905 | | 1400 | 31.1 | 730 | 1.565 | 26 | 6 | 75.6 |
Z4-225-21 | 49 | | 540 | | 1000 | 148 | 2470 | 0.2648 | 9.5 | 4.14 | 79.3 |
55 | | | 600 | 82.4 |
40 | | 450 | | 1000 | 125 | 0.397 | 13.7 | 5.41 | 76.6 |
45 | | | 500 | 78.9 |
Z4-225-31 | 119 | | 1360 | | 2400 | 327 | 2580 | 0.0454 | 1.5 | 5.33 | 89.3 |
132 | | | 1500 | 90.5 |
81 | | 900 | | 2000 | 227 | 0.093 | 3.4 | 5.3 | 86.9 |
90 | | | 1000 | 88 |
67 | | 680 | | 2250 | 197 | 0.167 | 5.1 | 5.44 | 82.5 |
75 | | | 750 | 85.1 |
Z4-250-12 | 144 | | 1360 | | 2100 | 399 | 2500 | 0.0444 | 1.3 | 4.29 | 88.8 |
160 | | | 1500 | 89.9 |
Z4-250-11 | 99 | | 900 | | 2000 | 381 | 0.0911 | 2.4 | 4.55 | 86.2 |
110 | | | 1000 | 88.1 |
Z4-250-21 | 167 | | 1360 | | 2200 | 459 | 2750 | 0.0325 | 0.91 | 4.28 | 89.8 |
185 | | | 1500 | 90.5 |
81 | | 680 | | 2250 | 234 | 0.1306 | 3.9 | 5.41 | 83.2 |
90 | | | 750 | 85.2 |