Dry Coolers for water free cooling with adiabatic system
Dry Cooler Features:
Unique floating coil design avoids leakage caused by thermal expansion and contraction.
Staggered fin pattern design and corrugated fin enhance air flow turbulence
Inner-grooved copper tube increase heat transfer area and enhance heat transfer
Optimized flow pass design ensure fully heat exchange with refrigerant
Equipped with 2nd generation owl-wing fan motor as standard. It features with low noise level, large volume flow and low energy consumption. Ready for dual speed connection.
Outdoor type powder coated casing made of galvanized sheet metal and stainless steel bolts provide a high resistance to corrosion.
Optional features:
EC variable speed fan motor, to save great energy
ZAplus/AxiTop for greater volume flow and extreme silence
Adiabatic system significantly reduce energy consumption in summer
Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
Fluid dry cooler
Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Dry Cooler Product showing
Dry Cooler Specification
Dry Cooler Features Air discharge direction | |
Performance ranges | Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Fluid coolers:customized on demand |
High efficiency heat exchanger | Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan | Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options | Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing. |
Dry Cooler Technical DataFluid cooler SHSL-D1 series parameter(fin space 2.1mm)
Type | SHSL-D1-005-1x350 | SHSL-D1-006-1x350 | SHSL-D1-007-1x350 | SHSL-D1-009-1x450 | SHSL-D1-011-1x450 | SHSL-D1-013-1x450 | SHSL-D1-014-1x500 | SHSL-D1-017-1x500 | SHSL-D1-020-1x500 |
Capacity | Water | 35ºC outdoor temp. | Inlet | 45ºC, | △ | KW | 4.89 | 5.90 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.80 |
outlet | 40ºC | Y |
20% Glycol | Inlet | 45ºC | △ | 4.72 | 5.69 | 6.69 | 8.90 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 |
outlet | 40ºC | Y |
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.20 | 1.63 | 1.91 | 2.30 | 2.50 | 3.00 | 3.50 |
Pressure drop | kPa | 36.00 | 31.00 | 58.00 | 25.00 | 40 | 80 | 50 | 60 | 40 |
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 |
Y |
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 |
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 |
Y |
△ | A | 0.60 | 0.60 | 0.60 | 1.10 | 1.10 | 1.10 | 1.45 | 1.45 | 1.45 |
Y |
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 |
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 |
Y | 10m |
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 |
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 |
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 |
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 |
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- |
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- |
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 |
Inlet φ | mm | 3/4" | 3/4" | 3/4" | 1" | 1" | 1" | 1-1/4" | 1-1/4" | 1-1/4" |
Inlet φ | mm | 3/4" | 3/4" | 3/4" | 1" | 1" | 1" | 1-1/4" | 1-1/4" | 1-1/4" |
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Note: Standard SHSL-D1 remote radiator is vertical air discharge, for horizontal air discharge please add "H" in nomenclature, for excmple:SHSL-D1-005H-1X350
Our factory for Dry Cooler - Advanced equipment
ReferenceClient visiting usOur certificateFAQQ1. Are you manufacturer or Trade Company?We are manufacture factory and we can accept OEM order.
Q2. What's the order process?1) Inquiry---provide us all clear requirements.
2) Quotation---official quotation list with all clear specifications.
3) PI--Confirm all the order technical data and price
4) Payment terms--- T/T deposit in advance
5) Production---mass production
6) Shipping--- by sea. Detailed picture of package will be provided.
7) After-sales Service--Any questions, we will try best to assist to solve for you.