China Galin Metal Manual Electroc Powder Coating/Spray/Paint Equipment (TCL-3) with Manual Gun, Find details about China Powder Coating Equipment, Powder Coating Gun from Galin Metal Manual Electroc Powder Coating/Spray/Paint Equipment (TCL-3) with Manual Gun
GALIN POWDER COATING EQUIPMENT (TCL-3) ELECTRICAL DATA | |
Nominal input voltage | 220V (100V-240VAC) |
Frequency | 50/60 Hz |
Input power | 40 VA |
Rated output voltage(to gun) | 12~18VPP |
Rated output frequency(to gun) | About20KHZ |
Protection type | IP54 |
Temperature rang | +10ºC to +40ºC (+50ºF to +104ºF) |
Solenoid Valve Voltage | 24VDC |
Gun output voltage | 0-100KVDC |
Gun output current | 0-100μA |
GALIN POWDER COATING EQUIPMENT (TCL-3) PNEUMATICAL DATA | |
MAX.input pressure | 8bar |
MIN.input pressure | 5bar |
Output pressure | 0~8bar |
Max.water vapor content ofthe compressed air | 1.3g/m³ |
Max.oil vapor content of the compressed air | 0.1mg/m³ |
Max.compressed air consumption | 19Nm³/h |
GALIN POWDER COATING EQUIPMENT (TCL-3) GUN PARAMETER | |
All the guns in the pictures match the Galin TCL-3 Equipment | |
Input | 12~18VPP |
Voltage Frequency | Around 22KHZ |
Input Current | <0.5A |
Output Voltage | 15~100KV Negative |
Max.Output powder volume | Around 600G/MIN |
Gun cable | 4 M |
Gun weight | 425g |
Error/cause | Troubleshooting |
Injector nozzle, non-return valve unit, powder hose or powder gun are clogged | Clean the corresponding parts and if necessary,replace them |
Conveying vacuum too low | Increase the powder quantity and/ or total air volume on the control unit |
Insert sleeve worn , not or incorrect inserted | Replace or insert it ,observe the indexing cam |
Insert sleeve is worm after a short operating duration | Clean the nozzle ,if damaged,replaced it |
The gun does not spray powder although the control unit is switched on and the gun trigger is pressed | 1.Connect the equipment to the compressed air 2.Clean /Replace 3.Clean the corresponding 4.Contact Galin representative |