Kyn61-36 Air-Insulated Metal-Clad Withdrawable Switchgear

China Kyn61-36 Air-Insulated Metal-Clad Withdrawable Switchgear, Find details about China Metal-Clad Switchgear, Withdrawable Switchgear from Kyn61-36 Air-Insulated Metal-Clad Withdrawable Switchgear

Model NO.
KYN61
Trademark
FARADY
Transport Package
Wooden Pallets
Specification
12KV/24KV/36KV/40.5KV
Origin
Zhejiang, China
HS Code
85371090
Model NO.
KYN61
Trademark
FARADY
Transport Package
Wooden Pallets
Specification
12KV/24KV/36KV/40.5KV
Origin
Zhejiang, China
HS Code
85371090
General
KYN61-36 air-insulated metal-clad withdrawable switchgear (hereinafter as switchgear is a kind of MV switchgea r.
It is designed as a withdrawable module type panel, and the withdrawable part is fitted with VD4-36E,VD4-36
withdrawable vacuum circuit breaker manufactured by FARADY Electric Company . It can also be fitted with isolation
truck, PT truck, fuses truck and so on. It is applicable to three phase AC 50/60 Hz power system,and mainly
used for the transmission and distribution of electrical pow er and control,protection,monitoring of the circuit.
Description of Product Model Number
Standards and Specifications
IEC60694 The commo n technical requirements of high voltage switchgear and controlgear
IEC62271-200 A.C. metal enclosed switchgear and controlgear at the rated voltage of 1kV~52k V
IEC62271-100 High voltage switchgear and controlgear-Part 100:Hi gh voltage A.C. circuit breaker
GB3906 3.6~ 40.5kV alternating current metal enclosed switchgea r and controlgear
GB1984 High voltage alternating current circuit breaker
GB/T11022 The commo n technical requirements of high voltage switchgear and controlgear
DL/T404 3.6~ 40.5kV alternating current metal enclosed switchgea r and controlgear
Normal Operating Conditions
A. Ambient temperature: -15 40
B. Ambient humidity:
Daily average RH no more than 95%;Monthly average RH no more than 90%
Daily average value of the steam pressure no more than 2.2k Pa, and montly no more than 1.8kPa
C. Altitude no higher than 1000m;
D. The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog;
E. External vibration from switchgear and controlgear or land quiver can be neglected;
F. The voltage of the secondary electromagnetism interference induced in the system shall no more than 1.6kV.
Special Operating Conditions
According to IEC60694, GB/T11022, the manufacturer and user may agree on special service conditions whic h
deviate from the normal service conditions.
To prevent the condensation phenomena,the heater is necessary for switchgear and needs to be put into service
when the switchg ear is in readiness and service conditons. The heat dissipation probl em of switchg ear can be
sloved by ventilation facilities.
 Technology Parameters:
Technology Parameters  
ItemUnitParameters
Rated Working VoltageV400
Rated FrequencyHz50/60
Rated CurrentHorizontal bus lineA1000-6300
Vertical bus lineA1000
Rated short-time tolerant current(1s)kA100
Rated peak tolerant currentkA220
Dielectric StrengthV/1min2500
Rated Insulation VoltageVAC660
Effective installed heightmm1800
Drawer Specification400mm Height(16E)mm250A≤In≤630A
200mm Height(8E)mm63A≤In≤250A
200/2mm Height(8E/2)mmIn≤63A
Control Motor CapacitykW300
Out shell protection level IP30/IP40
Shape dimension(Width×Length×Thickness)mm(400-1000)×1000×2200

Kyn61-36 Air-Insulated Metal-Clad Withdrawable Switchgear