Hot Sale 250 Tests/Hour Clinical Chemistry and Biochemistry Analyzer

China Hot Sale 250 Tests/Hour Clinical Chemistry and Biochemistry Analyzer, Find details about China Medical Equipment, Hospital Equipment from Hot Sale 250 Tests/Hour Clinical Chemistry and Biochemistry Analyzer

Model NO.
HP-CHEM250Y
Reagent Position
40 or 80 (Optional)
Reagent Volume
R1:1~400UL,1UL/Step ,R2:1~400UL,1UL/Step
Reaction Time
0~999 Seconds
Wavelength
340~810nm
Light Source
Halogen Lamp
Bar Code
Optional
Printer
Multiple Report Formats Available
Dimension
85*72*53(Cm)
Trademark
HEPOBIO
Transport Package
Standard Package
Specification
85*72*53(cm)
Origin
China
Model NO.
HP-CHEM250Y
Reagent Position
40 or 80 (Optional)
Reagent Volume
R1:1~400UL,1UL/Step ,R2:1~400UL,1UL/Step
Reaction Time
0~999 Seconds
Wavelength
340~810nm
Light Source
Halogen Lamp
Bar Code
Optional
Printer
Multiple Report Formats Available
Dimension
85*72*53(Cm)
Trademark
HEPOBIO
Transport Package
Standard Package
Specification
85*72*53(cm)
Origin
China
HP-CHEM250Y
HP-CHEM250Y Auto Biochemistry Analyzer is our new designed laboratory popular chemistry analyzer.Perfect designing with table top style,make it much fashion in your lab.And it can be produced by OEM style.
ModelHP-CHEM250Y
Assay ModelRandom Access with direct reading syatem
MethodEnd point,Kinetic,Fixed time,Immunoturbidimetry,1-2 reagent,Multistandard,reagent/serum blank,etc
Assay Item40 assay
ISE mould (Na+ ,K+,  Cl- /LI*) available on request
Throughput1Reagent257 tests/hour
2Reagent150 tests/hour
With ISE+120 tests/hour
Test MenuT.BILI    r-GT/GGT   CHO   Ca   APOB-1/B   CHE
D.BILI    ALP/AKP    TG    CL   APOB     CREA
TP        UREA     CK     P     CK-MB     Mg
ALB      CREA      LDH   C      ASO      AFU  
Lactic Acid ALT/GPT  UA     a-HBDH  CO2    FMN
LP(a)     AST/GOT  GLU   AMY   LDL-C   HDL-C
CHE        LA     TBA   ADA   HA-CRP    PA
FE         Cu       Zn      C3    C4        lgG   
IgM       lgA       and drug ,toxicity ,etc
Sample Position60
Including standard,control and stat,either serum cup primary tube available
Sample Volume1~100ul,0.1ul/step
Reagent Position40 or 80 (optional)
Reagent Volume R1:1~400ul,1ul/step ,R2:1~400ul,1ul/step
Reagent/Sample ProbeWith liquid level sensor,collision sensor,teflon coating and automatic washing station
Reaction Time0~999 seconds
CuvetteHigh quality uv-transmitted plastic cuvette,Quartz glass cuvettes
Cuvette Washing 8 channels automatic washing system for reaction cuvettes
Probe And Mixer Washing Independent washing station for each sample/reagent probe and mixer
AlarmAutomatic alarm for malfunction(eg:collision,reagent/sample insufficiency,full waste container,etc)
CallibrationLinear,Non-linear,Multi standard ,K factor
Sample Dilution/RetestSample can be diluted and retested if results are out of range or sample is insufficient,Also with calibrator auto diluting function
Wavelength340~810nm
Light SourceHalogen lamp
Absorbance Resoulution0.0001A
Absorbance Accuracy±0.0003A(0-2.5A)
Repeatability (CV%)≤2 %
Quality ControlLevy Jennings quality control program at 3 levels
Bar Code Optional
PrinterMultiple report formats available
Test Control FunctionNew card control system available on request
LanguageEnglish,French,Spanish,German,Russia.etc
SystemWindows XP or Vista ,Windows 7
Power Supply 220V/50HZ or 110V/60HZ  (optional)
Dimension85*72*53(cm)
Weight 85kg

After Sale and Complaint

1.After-sale Service Policy
 1)All our products are one year quality guarantee time generally.Longer guarantee can be refer to detailed offer.
 2)We will supply spare parts supports for most of our products for 5 years at least,and we will inform updated information for products supplied or stop production to our agent and showed them in our official website.
 3) If any quality problems such as design, manufacture, function or procedure occur within the guarantee period,we will in charge to maintain or supply spare parts for the equipment in reasonable ways or replacement the equipment if it certified to be needed.
 4)The cost for spare parts is free and labor is free too within guarantee period.And it will be charged by reasonable price out of guarantee period.The delivery fees,traffic frees and subsistence fees are charged accordingly or supplied by your side within and out of guarantee time.
 5)The primary positive response should be supplied through phone or email or other reasonable ways within 24 hours after getting the notice from agent or end users.And the details settlement program should be supplied by paper or email in days no more than 6 working days after getting the After-sale support from.
 6)We will provide a lifetime paid maintenance service and technical support for all our products out of guarantee period.And we will inform customers the update information for our products or suggest to clients to order the new model.
 7)End users or agent can make phone or fax or email for getting after-sale service for emergency and then fill the After-sale Support Form and send it to us by email or fax in time.
 8)HEPO INTERNATIONAL has a self-governed team for deal with after sales or complain business.

2,Complain Policy
 1)End users or agent can make phone or fax or email for complain for emergency and then fill the Complaint Form and send it to us by email or fax in time.The positive response time is same as upon clause in after-sale service.
 2)Customs' questions is first.If the goods received was breakdown or the package was damaged,we can arrange the new goods at once getting the inquiry from agent or purchaser along with pictures or other needed certified documents in our side.And we will bear half freight of sea shipment of this new order without any complain.The duty for the breakdown or damage of the head one can be deal after this new delivery.
 3)Once we delay delivery date,we will bear half freight for sea shipment for this order without any complain.

 

Hot Sale 250 Tests/Hour Clinical Chemistry and Biochemistry Analyzer
Hot Sale 250 Tests/Hour Clinical Chemistry and Biochemistry Analyzer