Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard

China Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard, Find details about China EKG Cable, Ge-Marquette Mac 1200 EKG Cable from Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard

Model NO.
MAC 1200
Biocompatibility
Latex Free
Cable Color
Grey
Cable Size
3.4m
Cable Material
Medical TPU
Cable Weight
0.5kg
Transport Package
23*18.5*4cm
Specification
2.2+1.2M
Origin
China
Model NO.
MAC 1200
Biocompatibility
Latex Free
Cable Color
Grey
Cable Size
3.4m
Cable Material
Medical TPU
Cable Weight
0.5kg
Transport Package
23*18.5*4cm
Specification
2.2+1.2M
Origin
China
Best selling GE Marquette EKG 10/12 Leadwires 3.0 , IEC/AHA Standard

Compatible with:
GE Healthcare > Marquette: MAC 1000, MAC 1100, MAC 1200, MAC 1600, MAC 2000, MAC 3500, MAC 400, MAC 500, MAC 600, MAC 800, Microsmart M

Technical Specifications:
ECG interpretation:Merquette ECG Analysis Program for Adults and Pediatrics
Computerized measurements:12-lead analysis
ECG analysis frequency:500 samples/second (sps)
Digital sampling rate:2,000 samples/second/channel
Dynamic range:AC Differential ± 5mV, DC offset ±300 mV
Resolution:4.88 μV/LSB @ 500 sps
Frequency response:-3 dB @ 0.01 to 150 Hz
Low cut-off frequency:0.01 Hz, 0.02 Hz, 0.16 Hz or 0.32 Hz (-3 dB limits)
High cut-off frequency:Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz
Common mode rejection:>100 dB (with AC filter switched on)
Input impedance:>10MΩ @ 10 Hz, defibrillator protected
Patient leakage:<10 μA
Heart rate meter:30 to 300 BPM ±10% or ±5 BPM, whichever is greater.  
Start-up time:Less than 7 seconds

Environmental Specification:
Temperature Operating:5°C to 40°CTransport/storage:-15°C to 50°C
Humidity Operating:25% to 95% RH non-condensing;Transport/storage:25% to 95% RH non-condensing
Pressure Operating:700 to 1060 hPATransport/storage:500 to 1060 hPA

SZMEPLUS offer:
P/NDescriptionConnector Imagine
MPK010AIEC     Din3.0       10K resistanceBest Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard
 
MPK010BAHA   Din3.0       10K resistance
MPK010CIEC     Banana     10K resistance
MPK010DAHA   Banana     10K resistance
MPK010EIEC     Snap         10K resistance
MPK010FAHA   Snap         10K resistance
MPK010GIEC     Clip           10K resistance
MPK010HAHA   Clip            10K resistance
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard






Payment: 
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard


Transportation Methods:
Best Selling Ge Marquette EKG 10/12 Leadwires IEC/Aha Standard

warranty:
1, Reusable spo2 sensors are carried 12 months warranty to repair for free due to the quality problems since  ex-factory;
2, ECG cable and leadwires, spo2 adapter cable, EKG cable are carried 6 months for free (excluding disposable spo2 sensor), but including the misuse, negligence or accidents causing from the buyer.

Return:
     For all warranty return items, prior authorization to return merchandise must be obtained by contacting SZMEDPLUS. If the items are not covered under warranty, customer is responsible for all shipping fee 25%  restocking fee.


Contact information:
Company name: ShenZhen Medplus
Contact Person:Jenie Wei