Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU

China Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU, Find details about China Active Power Transducer 4-20mA, Three Phase Active Power Transducer from Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU

Model NO.
BD-3P
Certification
CE
Customized
Non-Customized
Product Name
Three Phase Active Power Transducer
Brand
OEM ODM
Current Range
AC 0-5A AC100V 220V 380V
Output
4-20mA or 0-5V
Accuracy
Class 0.5
Auxiliary Power Supply
AC85-265V/DC 100V~350V/DC24V/DC 28V
Installation
Ts35mm DIN Rail Type
Trademark
ACREL
Transport Package
Fob Shanghai
Origin
China
Model NO.
BD-3P
Certification
CE
Customized
Non-Customized
Product Name
Three Phase Active Power Transducer
Brand
OEM ODM
Current Range
AC 0-5A AC100V 220V 380V
Output
4-20mA or 0-5V
Accuracy
Class 0.5
Auxiliary Power Supply
AC85-265V/DC 100V~350V/DC24V/DC 28V
Installation
Ts35mm DIN Rail Type
Trademark
ACREL
Transport Package
Fob Shanghai
Origin
China
Product Description

BD-4E  Three Phase Four Wire Electricity Transducer

General

BD series current transducer isolate and convert electrical parameters (e.g.current,voltage,frequency,power and power factor) in the power grid into DC analog signal or digital signal.The product complies with GB/T13850-1998 and IEC-688.


Features
- Measure AC current
- Overload: 1.2 times of rated value
- Analog Output DC 0-5V/0-10V/0-20mA/4-20mA
-RS485 (Modbus-RTU) communication
-Power monitoring application


 
Technical Parameters
 
Technical parametersValue
Accuracy 0.5class,0.2class
InputNominal valueCurrent :AC,DC 1A,5A;
Voltage: AC,DC 100V,300V,500Vand so on
OverloadContinual 1.2 times, Instantaneous current 10 times/5s;Instantaneous voltage 2 times /30s
Absorbed power≤0.3VA(Current input);Voltage input≤0.3VA(100V),≤0.6VA(300V),≤1VA(500V)
Frequency50±5Hz,60±5Hz
OutputNominal valueDC:4-20mA,0-20mA, 0-5V, 0-10Vand so on
Load ResistanceCurrent output ≤600Ω
Voltage output ≥1000Ω
Ripple content<0.5% peak value
Response time≤400ms
Power supplyVoltageAC85-265V/DC100-350V/DC24V/DC48V
PowerAC current, Voltage class ≤3VA,
Power Class ≤4VA
Insulation Resistance≥100MΩ
Isolation voltage(Among input//output//power supply)2.0kV/1min,50Hz
Temperature coefficient
 
0.5class≤200ppm/ºC; 0.2class≤100ppm/ºC
E  Environment
 
TemperatureWorking:-10ºC~+55ºC Storage:-25ºC~+70ºC
Humidity≤90%RH,(In the place without dew and corrosive gas)
Altitude≤2000m
Installation
 
(TS35 rail mounting, or attached with screws in of the cabinet)

Types
NameModelFunctionOptional Function
Current TransmitterBD-AIMeasurement of single-phase AC current, isolation transmission output 4-20mA or 0-5V DC signalRS485-MODBUS(C)
BD-3I3Measurement of three-phase alternating currents transmission output isolation 4-20mA or 0-5V DC signal/
Voltage transmitterBD-AVMeasuring AC voltage isolation transmission output 4-20mA or 0-5V DC signalRS485-MODBUS(C)
BD-3V3Three-phase three-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signal/
BD-4V3Phase four-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signal
Power transmitterBD-4EAThree-Phase four-wire multi-power transmitter, measuring and displaying exports three-phase current, voltage ,active power, reactive power ,frequency ,power factor, active energy; reactive energy and so on, 1~4 channel analog  optional, two channel electric energy
pulse output,RS485-MODBUS
M- Analog output, selectable 1 channel, 2- channel, 3- channel, 4- channel
Frequency transmitterBD-FMeasure frequency, transmit frequency into linear DC signal output/
Active power transmitterBD-3PThree-Phase 3-wire,Measurement of active power, isolation analog signal transmission output/
BD-4PThree-Phase 4-wire,Measurement of active power, isolation analog signal transmission output/
Reactive power transducerBD-3QThree-Phase 3-wire,Measurement of reactive power, isolation analog signal transmission output/
BD-4QThree-Phase 4-wire,Measurement of reactive power, isolation analog signal transmission output/
P / Q combination transmitterBD-3P/Q/IThree-Phase 3-wire,Measuring current, active power, reactive power, isolate analog signal transmission output/

Dimension(Unit:mm)
Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU




Wiring
Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU


                                                        Power Supply: AC85~265V DC100~350V
                                               

Certificate
Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU




Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU
Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU

Acrel Bd-3p AC Input AC 0-1/0-5A 0-125/250/450V Three Phase Active Power Transducer with Analog Output DC 0-5V/0-10V/0-20mA/4-20mA Optional RS485 Modbus-RTU