12V7A AC/DC desktop power adapter
The power adapter is 90W desktop type adapter series .This product is equipped with a 2-pin
C8 power plug,adopting the input range from 100VAC to 240VAC.The entire series supplies
output voltage between 5VDC and 48VDC that can satisfy the demands for various types of DC
consumer electronic devices.The effiency is not lower than 84% and designed accordion to UL/
CE/FCC safty regulations.
Features:
Universal Input 100-240 VAC |
2 pin C8 AC inlet |
Output with Low Ripple Noise |
Efficiency 88%min |
Class II power (without earth pin) |
Protections: | Short circuit/Overload/Over voltage |
Fully enclosed plastic case |
LED indicator for power on |
100% full load burn-in test |
CE/FCC and RoHS Certified |
Desktop Style / Non-vented Case |
Case Dimension (L*W*H mm): | 142*62*35mm |
Modified and Custom Design Available |
2 years warranty |
Iutput Characteristics
Input Voltage: | 100~240V AC |
Input Voltage Range: | 90-264VAC |
Rated Input Frequency: | 50Hz or 60Hz single phase. |
AC Input Frequency Range: | 47Hz to 63Hz |
Output Characteristics
Rated Voltage: | 5V~48V optional |
Output voltage regulation precision: | ±5% |
Loading regulation: | ±1% |
Ripple : | 1% Vp-p max. |
Transient Response : | 0.5ms for 50% Load Change Typical |
Protection: | Fold back Overcurrent Protection; Short Circuit Protection |
Environmental Conditions
Operating temperature: | 0ºC~40ºC |
Operating humidity: | 20%~ 90% (Relative humidity). |
Storage temperature: | -20ºC ~ 70ºC . |
Storage humidity: | 5%~ 95% . (Relative humidity). |
Cooling:By natural air flow |
Immunity
Dielectric Withstand Voltage ( HI-POT ): | HI-POT-A IEC 320 2pin primary to secondary 3000Vac 5mA 1min |
Safety Approvals: | CE /RoHS Certified and Designed according to UL/ standards |
Reliability
MTBF (Mean-Time-Between-Failures) Calculation: | MTBF shall be 50K hours of continuous operation at 20ºC, maximum load and normal voltage |
MTBF Verification: | The MTBF shall be verified from life testing performed by factory Quality Department. The operating conditions are: 40ºC ambient temperature , sea level , both nominal line voltage ranges (230Vac) and a minimum load of 70% of the maximum load. |