Manual Biphasic Cardiac Defibrillator Monitor

China Manual Biphasic Cardiac Defibrillator Monitor, Find details about China Defibrillator Monitor, Defibrillator from Manual Biphasic Cardiac Defibrillator Monitor

Model NO.
PT-9000B
Anesthesia
Closed Circuit
Type of Operating Light
Double Operating Light
Color
White
Defibrillator Type
Manual, Synchronized,Asynchronized
Charging Time
Maximum 10 Seconds to 360 Joules
Power Supply
AC 100V~240V,50Hz/60 Hz
LCD Dimensions
10.4 Inch
Trademark
SEEUCO
Specification
CE, ISO13485
Origin
Nanjing, China
Model NO.
PT-9000B
Anesthesia
Closed Circuit
Type of Operating Light
Double Operating Light
Color
White
Defibrillator Type
Manual, Synchronized,Asynchronized
Charging Time
Maximum 10 Seconds to 360 Joules
Power Supply
AC 100V~240V,50Hz/60 Hz
LCD Dimensions
10.4 Inch
Trademark
SEEUCO
Specification
CE, ISO13485
Origin
Nanjing, China
Features:
Physical characteristics:
Main unit: Desktop
Dimensions:L410xW360xH260              
Weight:12kg


Specifications:
1.DEFIBRILLATOR.
1.1 Defibrillator type:Manual, Synchronized, Asynchronized                                                                             
1.2 Energy accuracy:∠+1%
1.3 Energy selection :0, 20, 50, 100, 160, 250, 300, 360 joules (nominal at a resistance of 50)
1.4 Charging time :Maximum 10 seconds to 360 Joules
1.5 Standard Adult/Pediatric Paddles:Reusable external adult paddles(pediatric paddles integrated)     
      
2.Power requirements
2.1 AC Power supply :100V~240V,50Hz/60 Hz   
2.2  Vehicle Voltage(Option) :DC 12V

3.Internal Battery Backup
3.1 Battery type:Rechargeable lead-acid battery (12V 2.0Ah  X2)
3.2 Charging time:Time-Minimum of 4 hours for full charging    
3.3 Battery charging:During AC Power Supply operation of the device.
3.4 Charging /Low Battery Indication :Red LED                
3.5 Battery Capacity:100% of the battery will provide 120-min of monitoring; and 35 discharges at 360 joules.

4.Display
4.1 LCD Dimensions:10.4 inch
4.2 Type :High resolution true-color graphic LCD

5.ECG
5.1 ECG lead: I, II, III, AVR, AVL, AVF, V1~V6
5.2 S-T segment analysis: -2.0~2.0mv
5.3 Arrhythmia analysis: yes
5.4 Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

6.Respiration
6.1 Measurement method: Thoracic impedance

7.NIBP
7.1 Working mode: Manual/Automatic/stat
7.2 Method: Automatic oscillation
7.3 Cuff type: standard Adult; optional Pediatric/Neonatal

8.Temperature
8.1 Measurement range 20~45ºC
8.2 Resolution 0.1ºC

9.Pulse Oximetry(spO2)
9.1 Display :spo2 value, pulse histogram, waveform, Pulse
9.2 Range: 0~99%for adult, pediatric and neonatal patients
9.3 Probe :standard adult finger clip
9.4 optional pediatric Y-type clip and neonatal wrap

10.Pulse range
10.1 Pulse range: 0-255bpm

11.Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR

12.Optional parameter
Recorder, Li-ion battery (11.1V 4Ah  X2)
colorwhite