Optional Function Sections Energy Recovery Core Horizontal Ahu

China Optional Function Sections Energy Recovery Core Horizontal Ahu, Find details about China Air Handling Unit, Air Handling Unit Energy Saving from Optional Function Sections Energy Recovery Core Horizontal Ahu

Model NO.
HJK
Certification
ISO, CCC
Condition
New
Install Type
Floor
Panel Type
Single or Double Skin
Airflow
2000-10000 CMH
Panel Thickness
25/ 50mm
Heat Recovery Section
Plate or Eurovent Rotary Heat Exchanger
Filter
Coarse: G2, G3, G4, Medium:F5~F8
Heating and Cooling System
Optional
Control System
Optional
Cooling Method
Chilled Water
Feasures
Energy Recovery+Air Handling
Trademark
HOLTOP
Transport Package
Wooden Pallet
Specification
ISO9001, ISO14001, OHSAS18001
Origin
Beijing, China
HS Code
8415822000
Model NO.
HJK
Certification
ISO, CCC
Condition
New
Install Type
Floor
Panel Type
Single or Double Skin
Airflow
2000-10000 CMH
Panel Thickness
25/ 50mm
Heat Recovery Section
Plate or Eurovent Rotary Heat Exchanger
Filter
Coarse: G2, G3, G4, Medium:F5~F8
Heating and Cooling System
Optional
Control System
Optional
Cooling Method
Chilled Water
Feasures
Energy Recovery+Air Handling
Trademark
HOLTOP
Transport Package
Wooden Pallet
Specification
ISO9001, ISO14001, OHSAS18001
Origin
Beijing, China
HS Code
8415822000

Optional Function Sections Energy Recovery Core Horizontal Ahu
Introduction of Air Handling Unit,


1)Suspended on the ceiling or Vertical
2)Multi-functional
3)Heat recovery functions (Eurovent Heat Exchanger)
4)Excellent thermal insulation
5) Airflow 2000~100000CMH

Main features
1) Equipped with supply fan and exhaust fan, brings in fresh air and exhausts out stale indoor air as well.
2) Equipped with rotary heat exchanger, recovers energy from outgoing indoor air, to save operating cost to the max.
3) Thin height, easily installed in the ceiling space.

Housing construction
1) Double skin panel
25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high density fireproof PU with thermal coefficient below 0.0199W/m Degree.
2) High air tightness
Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3%.

Supply fan and exhaust fan
Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level.

Filter
Plate type(G4) coarse filter as standard configuration. (Bag filter F5~F8 available as per request of customer). Draw-push installation, easy maintenance.

Eurovent Rotary heat exchanger
Holtop total heat exchanger (enthalpy recovery wheel) is made of aluminum foil coated with 3A molecular sieve, which enables the wheel to exchange both temperature and humidity, in another word, to recover both sensible and latent heat.

Operation and maintenance
1. AHU is powered by TN-S power supply system, i. E. AC3~380V+N+PE.
2. Check and make sure motor runs at right direction and freely. Run the unit after all the electric parts are checked without fault by a professional.
3. Commissioning is required before putting the equipment into use. Motors should be running under rated electric current.
4. Cooling & heating coil should use clean demineralized water as medium, working pressure ≤ 1.2MPa.
5. Drain out the water in the coil in winter, and blow away the remains water as far as possible. In case remains water can not be blew away, inject antifreeze into the coil.
6. Examine the filter regularly, clean or replace it if resistance comes to the end resistance. Air-dry the washed fil- ter totally before reuse.
7. Fully clean or maintain the unit after each 1 or 2-year operation. Clean the coils using compressed air or high pressure water.
 
No.Part NameMaterialDescription
1Unit panelexternal plate material is colorful steel sheet t0.4mm, specialized for air conditioningelegant apprearance, dignity,high corrosion resistance
inner plate material is galvanized steel sheet t0.5mmadopt spangle-free
2Panel heat preservationhigh pressure foamed polyurethane t 50mmgood insulation performance, high strength, foaming ratio 40Kg/m³
3Other heat preservationpolyethylene foaminggood insulation performance
4Unit framet 1.0mm  colorful steel sheet framecorrosion resistance, long product life,  high strength
5Copper tube of cooling coilØ12.7mm copper tube,  wall thickness 0.41mmphosphorized seamless copper tube, good heat-transfer
 
6Cooling coil finØ12.7mm copper tube, adopt aluminium foil t0.15mmaluminium foil surfact dealt with acrylic resin
7Cooling coil header/pipingseamless steel pipe, taper pipe weldedHVAC special pressureizated seamless steel pipe
8Drain panstainless steel,  ( cold-roll steel sheets spray treatment  t1.5mm, optional standard type)corrosion resistance,long product life,clean
9Rotary heat exchangersensible, 0.05mm heat exchang aluminum foilhigh efficient heat exchange, clean-self
10Primary filterG4 synthetic plate type ,PVC framenon-woven
11Secondary filterF7 synthetic bag type ,PVC framenon-woven
12Supply fan/Exaust fanBelt drive multi-blade anteverted centrifugal fanhigh-quality bearings, good performance,low noise
13DamperRubber dampergood elastictiy,good vibration reducing performance,low the noise
14Braid connection PVC coatingB1 flame-proof type
15Unit base C type steelsurface spraying treatment, high strength, high corrosion resistance
16Package form wood pallet, wrapping film 