Ultraviolet Water Sterilization with Pneumatic Cleaning System
There are several advantages of using UV water filtration system rather than a chemical
disinfection solution (such as chlorination):
1.No known toxic or significant nontoxic byproducts
2.No danger of overdosing
3.Does not require storage of hazardous material
4.Adds no smell to the final water product
5.Requires very little contact time
Ultraviolet sterilizers use ultraviolet (UV) light to disinfect system water, destroying any waterborne pathogens. Unlike chlorine or bromine, UV sterilization leaves no toxic residuals in the water which may be harmful to the animals.
The sterilizer assembly consists of ultraviolet sterilizing lamp, quartz sleeve, and housing.
UV sterilization exposes the contaminants with a lethal dose of energy in the form of light. The UV light will alter the DNA of the pathogens, by virtually gluing DNA molecules together. The changed cell structure prevents the organism from reproducing itself (sterilization), therefore eliminating it.
Product application
Ultraviolet water purification systems are used in many applications that includes home/residential (both well water and municipal water supplies), commercial, and industrial. Here is a list of several applications where the power of UV water sterilizers are commonly used to treat and protect the water supply for contaminates such as bacteria and viruses. UV systems applications include private wells, campgrounds, hotels, bottlers, aquaculture, hospitals, food, cottages, restaurants, breweries, water systems, laboratories, marine, pharmaceutical, dairies and many other applications.
Principle of Operation
The optimum solution to remove ecoli , cryptosporidium , coliforms and all bacteria from your water is to install a Nature's Water Ltd. Ultraviolet Water Sterilizer. This will then allow you to have 100% bacteria free water in your premises - NO MORE VIRUSES OR BACTERIA! We can call and install the system for you. Click here for more information. If required we can call to you and assess your premises for location and workings of the system first-hand, Click here for a free call-out. If you would like a full water analysis from the laboratory to ensure that Coliform Bacteria is the only issue click here to arrange a water test.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
model | Processing capacity (Ton/Hour) | power (W) | inlet and outlet (inch) | working pressure (Kg/cm 2 ) | malfunction alert for UV lamp | reactor dimension (cm) L×W×H | dimension of panel(cm) | anchor bolt (cm) | overall weight (Kg) |
YLCn-005 | 0.3 | 16 | 1/2" | 6 | matched | 30×6×11 | | | 5 |
YLCn-008 | 1 | 25 | 1/2" | 6 | matched | 47×6.3×11 | | | 10 |
YLCn-050 | 2 | 40 | 1" | 6 | matched | 100×9×20 | Φ8.9×25 (diameter×length) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4" | 6 | matched | 100×11×23 | 69×4×Φ1 | 30 |
YLCn-200 | 8 | 120 | 1+1/2" | 6 | matched | 100×15.9×30 | Φ8.9×45 (diameter×length) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2" | 6 | matched | 100×15.9×32 | 69×7×Φ1 | 40 |
YLC-050 | 2 | 40 | DN25/1" | 6 | matched | 100×8.9×30 | 25×30×12 (L×H×w) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/1 1/4 " | 6 | matched | 100×10.8×30 | 60×4×Φ1 | 50 |
YLC-200 | 8 | 120 | DN40/1 1/2 " | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 60 |
YLC-300 | 12 | 160 | DN50/2" | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 70 |
YLC-360 | 15 | 200 | DN65/2 1/2" | 6 | matched | 100×15.9×40 | 50×78×25 (L×H×W) | 60×7×Φ1 | 120 |
YLC-500 | 20 | 240 | DN65/2 1/2" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 130 |
YLC-600 | 25 | 280 | DN80/3" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 140 |
YLC-700 | 30 | 320 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 150 |
YLC-1000 | 40 | 360 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 160 |
YLC-1200 | 50 | 400 | DN125/5" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 180 |
YLC-1500 | 60 | 420 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 210 |
YLC-2000 | 80 | 560 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 220 |
YLC-2500 | 100 | 700 | DN150/6" | 6 | matched | 170×27.3×57 | 60×128×30 (W×H×T) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6" | 6 | matched | 173×27.3×57 | 120×16×Φ1.4 | 300 |
YLC-4000 | 150 | 1120 | DN200/8" | 6 | matched | 173×32.5×65 | 120×20×Φ1.6 | 325 |
YLC-5000 | 200 | 1400 | DN200/8" | 6 | matched | 173×37.7×72 | 120×22×Φ1.6 | 350 |
YLC-7000 | 300 | 2100 | DN250/10" | 6 | matched | 175×42.6×80 | 120×24×Φ2.0 | 400 |
YLC-10K | 400 | 2520 | DN250/10" | 6 | matched | 176×52.9×95 | 60×150×40 (W×H×T) | 120×28×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12" | 6 | matched | 176×78×110 | 120×32×Φ2.4 | 600 |
YLC-20K | 800 | 3920 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed | confirmed |
YLC-25K | 1000 | 4760 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed |
Q. Are UV sterilizers a good replacement for biological and mechanical filtration?
A. NO. UV sterilizers are not a replacement for good biological and mechanical filtration, regular water changes, or proper control of the nitrogen cycle.
A properly selected UV sterilizer can help clarify water, rid free-floating algae, and control outbreaks of harmful bacteria and certain parasites.