Catheters Wire

China Catheters Wire, Find details about China Hospital Equipment, Hydrophilic Coating from Catheters Wire

Model NO.
INNO-Hydrowire
Flex L
3cm
Qty
5
Stiffiness
Standard or Hard
Tip Shape
Angle or Straight
Trademark
Innomed
Specification
SW-35-150-A-3-D
Origin
Suzhou
Model NO.
INNO-Hydrowire
Flex L
3cm
Qty
5
Stiffiness
Standard or Hard
Tip Shape
Angle or Straight
Trademark
Innomed
Specification
SW-35-150-A-3-D
Origin
Suzhou
 
 
Company Profile
Suzhou Innomed Medical Device Co., Ltd. (Innomed) is an innovative technology enterprise engaged in the development and manufacturing of interventional and implantable medical devices. The headquarter has an ISO13485 certified manufacturing plant with on-site clean room. 
Founders and senior management team of Innomed have extensive expertise ranging from medical device development and discovery, use of advanced implantable materials, product design and evaluation, manufacturing process optimization, quality, clinical, and regulatory implementation, and staff managing and development. The R&D team has profound experience and solid track records in early stage product development to product market launch in various
Catheters WireCatheters Wire
 


Production Line
Catheters WireCatheters WireCatheters Wire


Cerificate
Catheters WireCatheters WireCatheters Wire


 
 



PACKAGE CONTENTS
One Guidewire sterilized with Ethylene Oxide
CAUTIONS
• Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner.
• This device should be used only by physicians trained in angiography and percutaneous transluminal angioplasty (PTA).
• Read all instructions prior to use.
• Do not use if the package or sterile barrier is damaged or open.
• Use the guidewire prior to the "Use by" date on the package label.
• This a "Single Use Only" Guidewire - do not reuse or re-sterilize. Reprocessing may affect the functional integrity of the device. Incomplete sterilization may compromise malignant cross infection among patients.
• Refer to the instructions provided with other interventional devices to be used in conjunction with the Inno-Hydrowire for their intended use and contraindications.
 
DEVICE DESCRIPTION
The Inno-Hydrowire is intended to direct a catheter to the desired anatomical location in the vascular system during diagnostic or interventional procedures. It is provided sterile and is intended for single use only. It consists of a Nickel-Titanium alloy core wire; a polymer coating (Pebax containing BaSO4 for X-Ray visibility); and a hydrophilic coating applied to the entire wire. There are two shaft configurations: standard and stiff. There are two distal tip shapes: straight and angled. The Inno-Hydrowire includes a 3cm flexible tip. The Inno-Hydrowire is packaged in a plastic dispenser that is contained within an individual package. A Torquer is included which connects to the proximal end of the guidewire utilized for rotating and controlling the guidewire. The guidewires are packaged within a cardboard box which contains five individual guidewires.
 
INDICATIONS FOR USE
The Inno-Hydrowire Guidewire is intended to direct a catheter to the desired anatomical location in the vascular system during diagnostic or interventional procedures. This device is not intended for neurovasculature or coronary vasculature.
 
CONTRAINDICATIONS
The Inno-Hydrowire Guidewire is not intended for use in:
• The neurovasculature
• The coronary vasculature
• Patient judged not acceptable for percutaneous intervention
 
WARNINGS
• Do not manipulate or withdraw the guidewire through a metal needle or dilator.
• Do not advance or withdraw the device against resistance of unknown origin. Determine the cause by X-Ray and take necessary actions. Excessive force against resistance may result in vessel perforation /or damage.
• Do not attempt to use the guidewire if it has been bent, kinked or damaged.
• Do not put the guidewire into organic solvent, which may cause damage to the guidewire or its lubricity.
• Do not shape (reshape) the guidewire by any means. Reshaping the wire may cause damage and fracture.
• A torquer is included with guidewire, which is used to rotate and control the device. It cannot be inserted into the patient at any time.  
• The guidewire is to be used by a physician who is thoroughly trained in the insertion, manipulation and observation of guidewires under fluoroscopy.
• The device should be disposed safely and properly, following local regulations and laws.
 
PRECAUTIONS
• Physicians should evaluate the suitability of the device or select appropriate specifications of the device according to the patient's own condition and his/her own training skills and experience.
• The device must be moistened prior to removal from the dispenser in order to ensure lubricity. Heparinized physiological saline solution is recommended.
• Prior to reinsertion of the device during the same procedure, the wire should be rinsed in heparinized saline solution. Residual blood or other foreign matter can be removed by wiping the device with gauze that has been moistened with heparinized saline solution. Cleaning will not completely remove foreign substances, therefore the device is for SINGLE USE only.
 
DIRECTIONS FOR USE
1) Prepare the guidewire and any interfacing devices according to the manufacturer's directions.
2) Using sterile aseptic technique, remove the guidewire and the loop together from the package in the sterile field.
3) Using a syringe, flush the loop with heparinized saline solution through the tube of the loop to increase surface lubricity.
4) Remove the guidewire from the loop and inspect the guidewire prior to use; verify that it is lubricated.
NOTE: If the guidewire cannot be easily removed from the loop, inject more heparinized saline solution into the loop.
5) Prior to use, inject the catheter with heparinized physiological saline solution to ensure the guidewire can move easily within the catheter.
6) Tighten the torque at the proximal end of the wire and make sure there is no movement between them.
7) Keep at least 5cm of the tip of the wire out of the loop during introduction. Gently push and reverse the guidewire under fluoroscopy.
8) Holding the guidewire in position, advance the catheter over the guidewire and into the target lesion.
9) Complete the procedure and remove the guidewire and catheter according to standard procedural protocol.
10) Dispose of the guidewire according to your facilities hazardous waste policy.
Product Performance
Made of Nikle-titaniumalloy wire, it has good torsion control and support.
Visible under X-ray equipment, can accurately judge the moving status of guide wire.
The surface is coated with hydrophilic coating, which has good stability and increases the lubricity of the guide wire.