China 122kw 3 in 1 Charger/50kw CCS+50kw Chademo+22kwac Type 2, Find details about China CCS, Chademo from 122kw 3 in 1 Charger/50kw CCS+50kw Chademo+22kwac Type 2
1 | ON- OFF (Start-Stop) switches | Mandatory |
2 | Emergency stop switch | Mushroom headed Push button type in Red Color, visible and easily accessible |
3 | Visual Indicators | Error indication, Presence of input supply indication, State of charge |
process indication and other relevant Information | ||
4 | Display | Minimum 3.5" inches with 720 x 480 pixels TFT LCD Screen, user interface with touch screen or keypad 3 displays, 1 for each of CCS, CHAdeMO and AC Type-2 Toughened unbreakable glass to be used for display screen. |
5 | Support Language | English (with provision for additional regional languages including Hindi). |
6 | Display Messages | EVSE should display |
appropriate messages for | ||
user during the various | ||
charging states like: | ||
Suggestive sequence of | ||
charger operation | ||
Vehicle plugged in / Vehicle | ||
plugged out Duration since | ||
start of charge, kWh | ||
consumed. User | ||
authorization status | ||
Idle / Charging in progress: | ||
SOC Fault conditions | ||
Metering Information: | ||
Consumption Units for user | ||
during the various charging | ||
states like: | ||
Suggestive sequence of | ||
charger operation | ||
Vehicle plugged in / Vehicle | ||
plugged out Duration since | ||
start of charge, kWh | ||
consumed. User | ||
authorization status | ||
Idle / Charging in progress: | ||
SOC Fault conditions | ||
Metering Information: | ||
Consumption Units |
# Parameter Description | |||
General Requirements | |||
1 | EVSE Type | CCS + CHAdeMO + Type 2 AC | |
2 | Energy Transfer Mode | Conductive | |
3 | Charging mode | CHAdeMO-Mode 4, CCS - Type-2/Combo-2, AC - Type -2 Mode-3 | |
4 | Reliability and Serviceability | Modularity, self-diagnostic features, fault codes and easy serviceability in the field | |
System Structure | |||
1 | Regulation Method | Regulated D.C. EV charging station with combination of CVC or CCC but not simultaneously | |
2 | Isolation | Each output isolated from each other with proper Insulation | |
3 | Environmental conditions | Outdoor use | |
4 | Power supply | D.C. EV charging station connected to A.C. mains | |
5 | DC output voltage rating | 200-1000 V | |
6 | AC output voltage rating | 380-480 V |
7 | Charge control communication | Communicate by digital and analog signals | |
8 | Interface inter- operability | Inter-operable | |
9 | Operator | Operated by a trained person or EV Owner | |
Input Requirements | |||
1 | AC Supply System | 3-Phase, 5 Wire AC system (3Ph+N+E) | |
2 | Nominal Input voltage | 3Ø, 415V (+6% and -10%) as per IS 12360 | |
3 | Input Frequency | 50Hz, ±1.5Hz | |
4 | Input Supply Failure backup | Battery backup for minimum 1 hour for control system and billing |
unit, to enable activities such as billing, to be provided. | |||
Output Requirements | |||
1 | Output Details | As per table under Section 4.2.1 | |
2 | Number of Outputs | 3 | |
3 | Output Connectors | 3 output connectors | |
4 | Output Connector Compatibi lity | CCS: IEC 61851-23 / -24, IEC 62196-3, DIN 70121 CHAdeMO: IEC 61851-23 / -24, JEVS G 105, Rev. 1.2 compliant AC: IEC-61851-22, IEC 62196-2 Mode 3, Type 2 | |
5 | Converter Efficiency | > 92 % at nominal output power | |
6 | Power factor | ≥ 0.90 (Full load) | |
Cable Requirements | |||
1 | Charging Cable Length | 5 Meter, Straight Cable | |
2 | Cable Type | Charging cable and connector permanently attached to EVSE (liquid cooled) | |
Environmental Requirements | |||
1 | Ambient Temperature Range | -10°C to 55°C | |
2 | Ambient Humidity | 5 to 95% | |
3 | Ambient Pressure | 86 kpa to 106 kpa | |
4 | Storage Temperature | 0 to 60°C | |
Mechanical Requirements | |||
1 | Ingress Protection | IP 54 | |
2 | Mechanical Stability | Shall not be damaged by mechanical impact as defined in Section 11.11.2 of IEC 61851-1 | |
3 | Cooling | Air Cooled | |
4 | Mechanical Impact | Shall not be damaged by mechanical impact as defined in Section 11.11.3 of IEC 61851-1 | |
5 | Dimension (W*H*D)/Weight | Will be informed later | |
User Interface & Display Requirements |
1 | ON- OFF (Start-Stop) switches | Mandatory | ||
2 | Emergency stop switch | Mushroom headed type | ||
3 | Visual Indicators | Error indication, Presence of input supply indication, State of charge process indication | ||
4 | Display | Minimum 3.5" inches with 720 x 480 pixels TFT LCD Screen, user interface with touch screen or keypad. Toughened unbreakable glass for to be used for display screen. | ||
5 | Support Language | English (with provision for additional regional languages including hindi | ||
6 | Display Messages | EVSE should display appropriate messages for user during the various charging states like:
| ||
7 | Authentication | As per OCPP 1.6 or higher (through mobile application) | ||
Performance Requirements | ||||
1 | DC Output voltage and current tolerance | DC Output current regulation in Constant Current Charging (CCC): ± 2.5 A for the requirement below 50 A, and ± 5 % of the required value for 50 A or more DC Output voltage regulation in Constant Voltage Charging (CVC): Max. 2 % for the max rated voltage of the EVSE |