11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable

China 11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable, Find details about China 11kv Copper Power Cable, XLPE Insulated Cable from 11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable

Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
YJV
Specification
90mm2 150mm2 185mm2 240mm2 300mm2
Origin
China
HS Code
8544601200
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
YJV
Specification
90mm2 150mm2 185mm2 240mm2 300mm2
Origin
China
HS Code
8544601200
Structure 
Conductor: Solid or stranded copper/Aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Armouring: Single Core: AWA (Aluminium Wire Armour)
                   Multi Core:   SWA (Steel Wire Armour)  STA (Steel Tape Armour)
Sheath: Polyvinyl chloride (PVC)

 Application
1,Long term working temperature for the cable with PVC insulated is 70ºC;
Long term working temperature for the cable with XLPE insulated is 90ºC
2,Short circuit temperature
For PVC insulated cable ,the highest conductor temperature is not more than160ºC.(lasting time not over 5 seconds).
For XLPE insulated cable ,the highest conductor temperature is not more than250ºC.(Lasting time is not over 5 seconds).
3,Laying temperature not less than 0ºC and the drop height is out of consideration.
4,The cable with chemical stability, anti- acid, anti-alkali, anti-oil, anti-organic solvent, not easy to be burning.
5,Easy for installation, easy bending and light.



Operating characteristics
- Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
- Max.admissible operating temperature of the conductor:90ºC.
- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
- The ambient temperature under installation should not below 00C.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

Table of the voltage, cores and cross-section
ItemCategory    A ,B3.6/6kV6/10kV8.7/15kV12/20kV18/30kV21/35kV
Category    A ,B6/6kV8.7/10kV12/15kV18/20kV-26/35kV
Single coremm225-120025-120035-120050-120050-120050-1200
Three coremm225-40025-40035-40050-40050-40050-400

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.
5 Type and Name
TypeDesignationApplications
YJVCopper conductor,XLPE insulated,PVC sheathed power cableFor laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLVAluminum conductor,XLPE insulated,PVC sheathed power cable
YJYCopper conductor, XLPE insulated,PE sheathed power cable
YJLYAluminum conductor, XLPE insulated,PE sheathed power cable
YJV22Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cableFor laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cableFor laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable

 
 11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable
11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable

11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable
11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable
11kv Cu Conductor XLPE Insulated 3c 185mm2 240mm2 300mm2 Power Cable