Zw7 -40.5 Outdoor High Voltage Vcb Vacuum Circuit Breaker

China Zw7-40.5 Outdoor High Voltage Vcb Vacuum Circuit Breaker, Find details about China Circuit Breaker, Breaker from Zw7-40.5 Outdoor High Voltage Vcb Vacuum Circuit Breaker

Model NO.
ZW7-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
Certification
CE
Rated Voltage
40.5kv
Trademark
WEHOPE
Transport Package
Standard Export Package
Specification
Standard
Origin
China
HS Code
9107000000
Model NO.
ZW7-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
Certification
CE
Rated Voltage
40.5kv
Trademark
WEHOPE
Transport Package
Standard Export Package
Specification
Standard
Origin
China
HS Code
9107000000
General Introduction
ZW7-40.5 series VCB,is outdoor high voltage switch equipment with rated voltage 40.5KV,3-phase AC 50Hz.Design can meet the requirements of GB 1984"AC HIGH VOLTAGE BREAKERS",and comply with the requirements of C62271:100"HIGH VOLTAGE BREAKER"by International Electro technical Commission.ZW7-40.5 VCB,is mainly used for controlling and protection of the 35KV outdoor transmission system.It is also suitable for normal operation or short circuit protection of urban distribution,rural distribution and mining enterprises power system.The overall structure of this this kind of product is porcelain supporting type.Vacuum Interrupter is installed in upper porcelain,below is supporting porcelain.It is suitable for places need frequently operation,with features of good sealing,age-resistance,anti-high voltage,no burning,no explosion,long endurance life,easier for installing and maintenance,etc.

Main Technical Parameters(12KV)
sl.NoItemUnitData
1Rated voltageKV40.5
2Rated CurrentA 
3Rated short circuit breaking currenet KA2025
4Rated short-circuit current(peak)5063
5Rated short(thermal stable)current2025
6Rated peak withstand(dynamic stable)current5063
7Rated short circuit durationS4
8Rated insulation level(1min)1min power frequency withstand voltageDryKV95
Wet80
Lightning impulse withstand voltage(peak)185
9Rated operating sequencyTimes20
10Rated short-circuit current breaking timesms≤80
11Full-off time(with spring operating mechanism) O-0.3S-CO-180S-CO
12Mechanical life 10000
13Rated operating voltage AC110,220,DC110,220
14Contact opening distance 20
15Contact over-travelling distance 5±1
16Bounce time ≤5
17DC resistance per phase circuit ≤120
18Circuit Breaker Dimensions(L×W×H) 2460×2400×500
19Total Weight With Mechanismkg1100

Outline & Mounting Dimensions