++++General

SM66-40.5 unit type SF6 RMU with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, SM66-40.5 unit type SF6 RMU can completely meet the requirement of continuously variable market. It can take self-produced RLS-40.5 load break switch; also according to the demand of users can be assembled with the internationally top-ranking RCB series vacuum circuit breaker with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our VSC-40.5 type vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of "Four Controls" when matched with FTU and RTU.

++++Service enviromenet:

a) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-25ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2000m
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake

++++Units for all functions:

1. Incoming unit with switch disconnector(Load break switch) schemas with other extra components optional
2. Outgoing unit with Fuse-switch protection schemas with other extra components optional
3.Incoming/outgoing circuit breaker protection schemas with other extra components optional
4. MV metering schemas with other extra components optional
5. Casings (Bus bar Panel) schemas with other extra components optional

++++Main technical specifications:

 
No.ItemUnitParameter
1Rated voltagekV36
2Rated frequencyHz50/60
3Rated currentA1630
41min Power frequency withstand voltagekV80
5Lightning impulse withstand voltagekV195
6Rated short circuit breaking current (peak)kA50/40
7Rated active load/close circuit breaking currentA50/40
8Rated transferring currentA800
9Rated short circuit making current (peak)kA50/40
10Rated cable(line) charging breaking currentA50 and 10
11Cable charge breaking current in earthing faultA50
12Rated withstand current (peak)kA50/40
13Short time withstand current (2s)kA16
14Mechanism lifetimes2000
Note: For short circuit breaking and peak current is based on Fuse plus combination.

High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear
High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear
High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear





High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear
High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear
High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear
High Voltage Enclosed Type Sf6 Gas Insulated Ring Main Unit Switchgear