1 Pole Smart MCB Auto on/off RS485/Modbus RTU

China 1 Pole Smart MCB Auto on/off RS485/Modbus RTU, Find details about China Smart Circuit Breaker, Smart MCB from 1 Pole Smart MCB Auto on/off RS485/Modbus RTU

Model NO.
LS1-1
Poles Number
1, 2,3,4 Pole
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB
Model
Lr
Voltage(VAC)
230/415
Rated Current
100A
Frequency
50/60Hz
Trademark
LONGROAD/OEM
Transport Package
Box
Origin
China
Model NO.
LS1-1
Poles Number
1, 2,3,4 Pole
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB
Model
Lr
Voltage(VAC)
230/415
Rated Current
100A
Frequency
50/60Hz
Trademark
LONGROAD/OEM
Transport Package
Box
Origin
China
Package size per unit product
35.00cm * 70.00cm * 90.00cm
Gross weight per unit product
0.300kg
1.Overview
The smart MCB  is a building electrical terminal distribution device for smart safe power consumption and energy consumption management system.
The product is an intelligent circuit breaker for the Internet of things, which uses electronic technology to control the normal operation of traditional circuit breaker. It has remote opening and closing control, local mode selection, timing opening and closing settings, etc.
2. main functions
-Remote control: remote control ON/OFF, timing setting;
-Local control: local opening and closing, mode selection;
-Short circuit protection: automatic trip in case of short circuit fault;
-Overvoltage and undervoltage protection: it will trip automatically in case of overvoltage and undervoltage fault. It can set overvoltage and undervoltage threshold and enable opening and closing;
-Overtemperature protection: it will trip automatically when overtemperature occurs. It can set the threshold of overtemperature and pressure and enable to open and close;
-Metering function: real time monitoring of voltage, current and power, and metering of electricity consumption;
-Communication function: support RS485 communication interface, standard Modbus protocol
-Independent power supply (gateway function will be added later).
3.specification parameters

Pole number 1P, 2P, 3P, 4P
Rated Voltage 220V/380V
Rated current :16, 20, 25, 32, 40, 50, 63, 80, 100A
Type of instantaneous release C
Mechanical life (0 ~ C) twelve thousand
4. technical parameters of shunting
-Poles number: 1P,2P, 3P,4P
-Breaking current lcs=lcu≤6000A lcs=lcu≤6000A
-control mode: manual and automatic smart control
-Rated voltage: 220/230V 380/400V
-Rated current:10, 16, 25, 32, 40, 50, 63, 80,100A
-Communication mode :RS485
-Tripping characteristics :Type C instantaneous trip
Current 5-10in Type C instantaneous trip
Current 5-10in
ambient temperature: - 40ºC~70ºC - 40ºC~70ºC
relative humidity ≤95% ≤95%
Short circuit protection Power off time ≤ 0.04s
1 Pole Smart MCB Auto on/off RS485/Modbus RTU

1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU

 

1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU1 Pole Smart MCB Auto on/off RS485/Modbus RTU