AC Frequency Inverter Converter 50/60Hz 220V

China AC Frequency Inverter Converter 50/60Hz 220V, Find details about China Frequency Inverter, Frequency Converter from AC Frequency Inverter Converter 50/60Hz 220V

Model NO.
YCB/IST
Rated Current (a)
2.6A-
Outline Dimension (mm)
86X120X136
Weight (Kg)
26kg
Max Power (Kw)
0.75kw-800kw
Trademark
CNC
Specification
CE, ISO, CCC
Origin
Wenzhou, Zhejiang
Model NO.
YCB/IST
Rated Current (a)
2.6A-
Outline Dimension (mm)
86X120X136
Weight (Kg)
26kg
Max Power (Kw)
0.75kw-800kw
Trademark
CNC
Specification
CE, ISO, CCC
Origin
Wenzhou, Zhejiang
AC frequency inverter converter 50/60HZ 220V
 
1. Function

Variable frequency inverter is used in underground mines with explosive gas (methane) and coal dust. Main spare partsSuch as IGBT, filter capacitor, control core adopt imported brands to ensure reliable longtime
Operation. This series adopt vector control technique with perfect motor protection
And good speed adjusting to realize soft start and soft stop of the motor. According to the
Load circumstances, it can automatically adjust the motor speed and reduce the reactive
Impact of the motor starting on the grid. Meanwhile, through peripheral sensor, it can
Realize variable dynamic control to achieve the purpose of energy saving. Applicable to
Explosion-proof mine hoists, belt conveyor, scraper conveyor, pump station, fan etc. In the
Underground mines.


2. Characteristics

2.1 Adopt no-speed sensor vector. The output torque can reach 1.5 times rated torque at
0.5Hz. The largest torque is 2 times of the rated torque.
2.2 Heat pipe cooling ensures the cooling requirement of the equipment operation,
Reduces the system voice and realizes zero maintenance.
2.3 Wide frequency adjusting (2-16kHz) to meet demands of different occasions.
2.4 Different brake modes according to different loads: DC brake, dynamic brake, feedback
Brake
2.5 Human-Machine interface adopts intrinsically safe circuits for isolation purpose so that
It can ensure the equipment safety and convenient operation.
2.6 With protective functions of over-voltage, short-circuit, over-load, over-heating, phaseloss
Etc.
2.7 With standard RS-485 communication interface.
2.8 Good electromagnetic compatibility.


YCB100 general technical data

 

Item

Description

Input

Rated voltage,frequency

Three phase 380V~440V,50Hz/60Hz    

Output

Allowed working

voltage scope

Voltage: 320V~460V,voltage imbalance rate: 3%,frequency 5%  

Rated voltage

380V

Rated frequency

0~65Hz

Main control performance

Overload performance

G type:1 minute for 150% rated current,0.5 second for 200% rated current

P type: 1 minute for 110% rated current,1 second for 150% rated current    

Speed adjust method

Flux Vector PWM regulator  

Speed adjust

scope      1:100     

Starting torque

0.50Hz of 180% rated torque

Working speed stable precision

≤±5% rated synchronous speed

Frequency precision

Numerical setting: highest frequency ×0.01%,

Simulation setting: highest frequency ×±0.02%,      

Frequency resolution

Numerical setting: 0.01Hz

Simulation setting: highest frequency ×0.1%,

   

YCB200 general technical data

Item

Description

Input and Output characteristics

Input voltage scope

380/220V±15%

Input frequency scope

67~63Hz

Output voltage scope

0~rated output voltage

Output frequency scope

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 ways input

Programmable analog input

VI:0~10V input, CI:0~10V or 0~20mA input

Open collector output

1 way output

Relay output 1

Way output

Analog output 1

Way output, can select 0/4~20mAo or 0~10V

Technical performance characteristics

Control method

NO PG vector control, V/F control

Overload capacity

60s for 150% rated current and 10s for 180%rated current

Starting torque No.

PG vector control: 0.5Hz for 150% rated torque

Speed ratio NO.

PG vector control: 1:100

Speed control precision

NO PG vector control: ±0.5% highest speed

Carrier wave frequency

0.5K~15.0Hz

Functions

Frequency

Setting method digital setting, analog setting, serial communication

Setting method

Setting, multi-speed, PID setting etc.

PID control function

May constitute closed-loop control system easily

Multi-speed control function

8 speed control

Swinging frequency control function

Can achieve swinging frequency function with center frequency adjustable

Instantaneous power down non-stop function

Through the bus voltage control to achieve uninterrupted operation when power-down instantaneously

Speed tracking restart function

Achieve non-impulse start for rotating motor

JOG key function

Free multi-user-defined key

Automatic voltage regulation

When the voltage changes, it can automatically maintain a constant output voltage

Protect function

Protection of missing phase over current, over voltage, under voltage, overheating and overload

 AC Frequency Inverter Converter 50/60Hz 220VAC Frequency Inverter Converter 50/60Hz 220V
 AC Frequency Inverter Converter 50/60Hz 220V