Blood Pulse Oximeter

China Blood Pulse Oximeter, Find details about China Pulse Oximeter, Fingertip Pulse Oximeter from Blood Pulse Oximeter

HS Code
9018199000
HS Code
9018199000

Instructions 
Principle of the SD-50DL Pulse Oximeter is as follows:
Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Blood Pulse Oximeter

PerformanceSD-50DL1SD-50DL2SD-50D1SD-50D2
Display ModeLED display

Color  display

Power Supply1.5V (AAA size) alkaline batteries * 2  
Power Consumption
less than 25mA
less than 30mAless than 80 mA
Dimension61(L) mm * 36(W) mm * 32(H) mm60(L) * 30.5(W) * 32.5 (H) mm61(L) * 36(W) * 32(H) mm
60(L) * 30.5(W) * 32.5 (H) mm
WeightAbout 60g (with the batteries)About 50g (with the batteries))About 60g (with the batteries)About 50g (with the batteries)

 

Major Features


-- Integrated with SpO2 probe and processing display module
-- Small in volume light in weight and convenient in carrying
-- Operation of the product is simple ,low power consumption
-- SpO2 value display
-- Pulse rate value display, bar graph display
-- Pulse waveform display
-- The display mode can be changed
-- Screen brightness can be changed
-- Low-voltage indication

-- Automatically power off function: 

when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
-- Display format can be saved after power off

Main performance
-- Display Mode: 0.96" Color display

-- SpO2 Measuring Range: 0%-100%, (the resolution is 1%).
-- Accuracy: 70%-100%: ±2% ,Below 70% unspecified.
-- PR Measuring Range: 30bpmï½250bpm, (the resolution is 1bpm)
-- Accuracy: ±2bpm or ±2% (select larger)
-- Measurement Performance in Weak Filling Condition:
-- SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 -- error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
-- Resistance to surrounding light: The deviation between the value measured in the -- condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
-- Power Consumption: less than 30mA
-- Voltage: DC 3.0V
-- Power Supply:1.5V (AAA size) alkaline batteries  
 Battery working hour: Theoretical number is 32 hours.
-- Safety Type:Interior Battery, BF Type 

 

Content:

1. Pulse oximeter

2. Carry case

3. Landyard

4. Manual