Hot Sale Pressure Sensor Transducer

China Hot Sale Pressure Sensor Transducer, Find details about China Gauge, Pressure Gauge from Hot Sale Pressure Sensor Transducer

Customized
Customized
Trademark
Huatian
Transport Package
Standard Package
Origin
Tianshui, Gansu, China
Customized
Customized
Trademark
Huatian
Transport Package
Standard Package
Origin
Tianshui, Gansu, China
Hot Sale  Pressure Sensor Transducer
Features

·Wider pressure range;
·Full stainless steel construction; optional pressure port; flush diaphragm type, sanitation type and anti-corrosive type are available; protection IP65;
·Optional output signal; local calibration and displayable;
·Reversed-polarity, transient current & voltage protection, which conform to EMI standard;
·Intrinsic safe ex-proof version conforming to GB3836.4 ExiaII CT6 Regulation; Ex-proof Certificate is issued;
·EXD product conforming to GB3836.2 ExdII CT6 Regulation; EXD Certificate is issued.

Introduction
The transmitter uses piezoresistive pressure sensor with isolated stainless steel diaphragm as signal sensing element, through automatic testing, laser trimming compensating zero and sensitivity in wider temperature range; the amplifier circuit is in stainless steel housing, transforming sensor signal into standard output signal. Through strict component making, semi-finished product and all-finished product testing and aging, the transmitter is stable and reliable, having excellent flexibility, sensitivity and diversity.
The product is widely used for pressure measure and control of petroleum, chemi-industry, metallurgy, power station and hydrology, etc.

Specification
Pressure range: 0~100MPa
Overpressure: 1.5 times FS(min. value is valid)
Pressure type: gauge, absolute or sealed gauge
Accuracy: 0.2%FS/0.5%FS(typ.) 1.0%FS(max.)
Long-term stability: 0.2%FS/year(typ. 0.3%FS/year(max.)
Zero temp. drift: 0.03%FS/ºC(≤15PSI); 0.02%FS/ºC(>15PSI)
FS temp. drift: 0.03%FS/ºC(≤15PSI); 0.02%FS/ºC(>15PSI)
Operation temp. -20ºC~85ºC
Storage temp.: -40ºC~125ºC
Power supply: 9~36VDC
Output signal: 4~20mADC
Transmitting: 2-wire
Load: ≤(U-9)/0.02Ω
Protection: IP65 for both cable and plug connection
Electric connection: Plug connection or 1.5m cable connection
Housing: stainless steel 1Cr18Ni9Ti
Diaphragm: stainless steel 316L
O-ring: Viton

Outline Construction
(Unit: mm)
Hot Sale Pressure Sensor Transducer


Electric Connection
Plug Connection Wiring /Cable Connection Wiring
Pin2-wireColor2-wire
1+VRed+V
20V/+OUTBlack0V/+OUT