6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor

China 6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor, Find details about China Patient Monitor, 6 Parameters Patient Monitor from 6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor

Model NO.
MC-C
Working System
Continuous Running Equipment
Voltage
220V
Leads
3-5 Leads
Weight
3.1kg(with Lithium Battery)
Trademark
Mecan
Transport Package
Export Standard Packaging for Air and Sea
Specification
39mm X 30mm X 35mm
Origin
China (Mainland) Guangdong
Model NO.
MC-C
Working System
Continuous Running Equipment
Voltage
220V
Leads
3-5 Leads
Weight
3.1kg(with Lithium Battery)
Trademark
Mecan
Transport Package
Export Standard Packaging for Air and Sea
Specification
39mm X 30mm X 35mm
Origin
China (Mainland) Guangdong

6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor

Model: MC-G

6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor

Click here for more information !!!

What is the detail of our Blood Hematology Analyzer?

 

Basic information:

 

6 parameters

ECG,HR/PR,SPO2,NIBP,RESP, TEMP

Size

12.1 inch portable ICU monitor

Weight

3.1kg(with lithium battery)

Voltage

220v

Power

40w

Leads 

3-5 leads

Suitable places

Bedside care ward, ICU, CCU, operating theaters, emergency centers, family care and the like.

Optional

ETCO2 module; Build-in thermal printer; lithium battery; mobile stand/ wall mount

SFDA classification

Class II

Working system

Continuous running equipment

 

Features:

new high-precision modules, new digital oxygen technology

12" color TFT display, up to 12 waveforms
Arrhythmia analysis, ST calculation, Pace analysis

Various interfaces: A single guide, standard, large font, all leads
Anti-ESU, anti- defibrillator

Patient info input management function

Multi-lead ECG waveforms display in phase

 1-7 level audio/visual alarming 

Large volume of tabular and graphic trends information storage and easy to recall

Suitable for adult, pediatric and neonatal patient
Built-in recorder and battery

 

Click here for more information !!!

Standard configuration:

MC-G patient multi parameter monitor×1 set,

Rechargeable lithium battery×1 pcs,

standard 5-leads ECG conductance joint connecting cables×1 set,

standard adult blood pressure cuffs×1 set,

adult SPO2 probe×1 set,

TEMP probe×1 set,

power plug line×1 set,

grounding wire×1 set,

English operation manual×1 set.

Three certificates×1 set.

Optional:

EtCO2 module; Build-in rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ wall mount

 

Technical parameters

ECG

lead mode;I,II,III,AVR,AVL,AVF,V1-6

Gain: ×0.25, × 0. 5, and × 1, × 2

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 BPM

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-2.0mV----+2.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

NIBP

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Scope: Pressure Cuffs 0-250 mmHg

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Measuring range: SYS: 60-250 mmHg

DIA: 40-220 mmHg

MEAN: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

SYS: maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

DIA: ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254mmHg adjustable

SPO2

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling:     1% - 100% adjustable

Threshold:   0% - 99% adjustable

TEMP

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

RESP

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

Printer(Optional)

 

Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi  vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

System

Screen:12.1 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)

 

Click here for more information !!!
6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor
6 Parameters Patient Monitor ICU Monitor Multi Parameter Patient Monitor