1*25mm2+54.6mm2 Nfc 33209 Standard Aerial Bundled Cable for Overhead Electrical Wire Cable

China 1*25mm2+54.6mm2 Nfc 33209 Standard Aerial Bundled Cable for Overhead Electrical Wire Cable, Find details about China 25mm2 Aerial Cable, Aerial Bundled Cable from 1*25mm2+54.6mm2 Nfc 33209 Standard Aerial Bundled Cable for Overhead Electrical Wire Cable

Model NO.
Overhead electric wire cable
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, UL
Model
Jklyj NFA2X
Brand
Rneda
Certificate
UL CE TUV BV Kema SABS ISO
Cable
ABC
Insulation
XLPE
Rated Voltage
1000V
Size
16-300mm2
Core
1 2 3 4 3+1 3+1+1
Manufacturer
Aerial Cable
Price
Direct Factory Price
Trademark
RNEDA
Transport Package
Wooden Drum
Specification
IEC DIN ASTM VDE BS
Origin
China
HS Code
7614100000
Model NO.
Overhead electric wire cable
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, UL
Model
Jklyj NFA2X
Brand
Rneda
Certificate
UL CE TUV BV Kema SABS ISO
Cable
ABC
Insulation
XLPE
Rated Voltage
1000V
Size
16-300mm2
Core
1 2 3 4 3+1 3+1+1
Manufacturer
Aerial Cable
Price
Direct Factory Price
Trademark
RNEDA
Transport Package
Wooden Drum
Specification
IEC DIN ASTM VDE BS
Origin
China
HS Code
7614100000

Aerial Bundled Cable NFC 33209 Standard for overhead electrical wire cable 1*25mm2+54.6mm2

1, Standard and Scope of Application
The products adopt IEC 60502, it are mostly used for telecommunication systems or for power transmissions with voltages below 1000 volts. Aerial cable for voltages around 10000 volts have also been built, for the supply of farms, waterworks, transmitters and other facilities outside urban areas. Another common use is the replacement of overhead telecommunication lines, for example, along railway line, 

2, Specific Property for Using
A), the min. temperature of laying cable is not lower than 20°C.
B), the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is 250°C when short circuit (5 seconds ).
C), the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.
D), Every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours every year.
E), the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less than 15(D±d) ±5%mm.

Specification

Type
DescriptionApplication
JKVRated voltage 1kV copper core PVC insulation aerial cableAerial fixed installation,lead door line
JKYRated voltage 1kV copper core PEinsulation aerial cable
JKYJRated voltage 1kV copper core XLPEinsulation aerial cable
JKLVRated voltage 1kV aluminum core PVC insulation aerial cable
JKLYJRated voltage 1kV aluminum core XLPE insulation aerial cable
JKLJRated voltage 1kV aluminum core PE insulation aerial cable
JKLHYRated voltage 1kV Al alloy core PE insulation aerial cable
JKLHVRated voltage 1kV Al alloy core PVC insulation aerial cable
JKLHYJRated voltage 1kV Al alloy core XLPE insulation aerial cable