China 12" Touch Screen Patient Monitor 6 Parameters Patient Monitor, Find details about China Patient Monitor, Multi-Parameter Patient Monitor from 12" Touch Screen Patient Monitor 6 Parameters Patient Monitor
First, the performance characteristics of multi-parameter monitor :
1, using the world famous brand module, high precision, accurate parameters, reliable quality, stable performance
2, high brightness and high resolution 12-inch color TFT liquid crystal display, data waveform is clear and easy to see
3, the body is light and sturdy, easy to carry
4, internal all-metal structure, fully isolated floating, the parameters are more stable and reliable
5, rotating flying edge operation mode, Chinese and English dual-use operation interface, easy to learn, easy to use, easy to operate
6, using LFG full digital optical frequency oxygen measurement technology, pulse oximetry measurement is more accurate
7, full-lead seven-channel synchronous display ECG
8, five minutes ECG waveform playback, ST segment automatic detection, arrhythmia analysis, drug concentration calculation and other functions
9, full parameter 384 hours trend data memory and dynamic waveform capture
10, can set the upper and lower limits of the alarm arbitrarily, automatic sound and light double alarm
11, for adults, children, newborns
12, anti-defibrillation, anti-high-frequency electric knife interference
13, with network transmission function, the connection network cable can be directly connected to the computer, or send data packets through the network
14, ultra-quiet, fanless design
15, optional plug-in lithium battery, AC, DC dual-use
16, optional built-in dual-channel thermal array recorder, real-time printing of waveforms and charts
17, widely used in internal medicine, surgery, operating room, obstetrics and gynecology, pediatrics, emergency center, ICU, CCU
18, optional cart, wall bracket.
19, a variety of display interface, convenient and intuitive
ECG ECG
Lead selection: full lead, I, II, III, aVF, aVR, aVL, V1--6 chest lead display
Gain selection: ×1, ×2, ×4, ×0.5 four files
Frequency: Diagnostic mode 0.05~130Hz
Monitoring mode 0.5~40Hz
Surgical mode 1~20Hz
Common mode signal rejection: diagnostic mode > 90 dB
Monitoring mode > 100 dB
Surgical mode > 100 dB
Scanning speed: 12.5 mm / S, 25 mm / S, 50 mm / S three standard files.
Heart rate range: Adult 15 ~ 300bpm (beat / minute)
Newborn / Child 15 ~ 350 bpm (beat / minute)
Heart rate accuracy: ±1% or ±1bpm, whichever is greater
Calibration signal: 1mV (peak-to-peak value, accuracy ±5%)
ST segment detection: measurement range (-2.0mV ~ +2.0mV)
Baseline recovery time: < 3="" seconds="" after="">
Alarm mode: sound and light alarm
Heart rate alarm preset range: (over preset value alarm)
Adjustable from 40 to 255 times per minute
The lower limit is adjustable from 20 to 160 times per minute.
RESP breathing
Respiratory measurement range: Adult 7 ~ 120BrPM (times / min)
Children and newborns 7 to 150 BrPM (times / minute)
Accuracy: ±2 BrPM (times/min)
Resolution: 1 BrPM (times / min)
Gain selection: ×0.5, ×1, ×2, ×4 four files
Alarm mode: sound and light alarm
Alarm preset range: (over preset value alarm)
Adjustable from 10 to 100 times per minute
The lower limit is adjustable from 0 to 99 times per minute.
NIBP blood pressure
Technology: oscillometric method (pulse wave oscillation method)
Working mode: manual / automatic
Unit of measurement: mmHg / Kpa
Overvoltage protection: double safety protection
Adult mode 300 mmHg
Child mode 240 mmHg
Neonatal mode 150 mmHg
Blood pressure measurement range and accuracy:
range
Adult systolic blood pressure 40~270mmHg
Diastolic pressure 10~215mmHg
The average pressure is 20~235mmHg
Children systolic blood pressure 40~200mmHg
Diastolic pressure 10~150mmHg
The average pressure is 20~165mmHg
Neonatal systolic blood pressure 40~135mmHg
Diastolic pressure 10~100mmHg
The average pressure is 20~110mmHg
Static pressure range: 0 ~ 300mmHg
Static pressure accuracy: ±3mmHg
Blood pressure accuracy: maximum average error ±5mmHg
Maximum standard deviation 8mmHg
Alarm mode: sound and light alarm
Alarm preset range and error: (over the preset value alarm)
Systolic pressure upper limit 40 ~ 250mmHg; lower limit 10 ~ 220mmHg
Diastolic blood pressure upper limit 20 ~ 250mmHg; lower limit 10 ~ 220mmHg
SPO2 blood oxygen saturation
Range: 70 to 100%: ± 2 DIGIT 0% to 69%: not defined
Blood oxygen saturation measurement error: 70 ~ 100%: ± 2 0% ~ 69%: not defined
Resolution: 1%
Pulse times: 20 to 300 times / minute
Alarm mode: sound and light alarm
Alarm preset range and error: (over the preset value alarm)
The upper limit is 20% to 100%;
The lower limit is 10% to 99%;
TEMP body temperature
Technology: Highly sensitive thermistor probe
Body temperature measurement range: 0 ° C ~ 45 ° C
Resolution: 0.1 ° C
Temperature accuracy: ±0.1 °C (without sensor error)
Alarm mode: sound and light alarm
Alarm preset range and error: (over the preset value alarm)
Upper limit adjustable from 20.1 ° C to 45 ° C
Adjustable between 20°C and 44.9°C
Optional
lithium battery
Specifications: 2200MA lithium battery
printer
Specifications: Dual Channel Thermal Array Recorder
Printing method: real-time or event trigger recording waveform, text
This is a portable handheld Patient Monitor: