China Must Smarlmust Smart Powr Inverter Home Application Tower 10000 Watt Inverter, Find details about China Power Inverter, DC AC Power Inverter from Must Smarlmust Smart Powr Inverter Home Application Tower 10000 Watt Inverter
MODEL(EP20-Tower Type) | 600T | 1000T | 1500T | 2000T | 3000T | 4000T | 5000T | 6000T | 7000T | 10000T | ||||
Default Battery System Voltage | 12VDC | 12VDC/24VDC | 24VDC | 48VDC | 96VDC | |||||||||
INVERTER OUTPUT | Rated Power | 600W | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | 10000W | |||
Waveform | Pure sine wave | |||||||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(+/-10% RMS) | 220V/230V/240VAC(+/-10% RMS) | ||||||||||||
Output Frequency | 5OHz/60Hz +/-0.3 Hz | |||||||||||||
Inverter Efficiency(Peak) | >80% | |||||||||||||
Line Mode Efficiency | >95% | |||||||||||||
Power Factor | 1.0 | |||||||||||||
Typical Transfer Time | Typical 2~6ms ,10ms max | |||||||||||||
AC INPUT | Nominal Voltage | 100V/110V/120VAC 220V/230V/240VAC | 220V/230V/240VAC | |||||||||||
Voltage Range | 96~132VAC/145~275VAC(For Personal Computers) | 145~275VAC(For Personal Computers) | ||||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing 44-68Hz) | |||||||||||||
BATTERY | Nominal Input Voltage | 12VDC | 12VDC/24VDC | 24VDC | 48VDC | 96VDC | ||||||||
Minimum Start Voltage | 10.5VDC /21.0VDC/42VDC/84VDC | |||||||||||||
Low Battery Alarm | 10.5±0.3V /21VDC±0.6V/42VDC±1.2V/84VDC±2.4V | |||||||||||||
Low Battery Cutoff | 10.0±0.3V/20VDC±0.6V/40VDC±1.2V/80VDC±2.4V | |||||||||||||
High Voltage Alarm | 15.5±0.3V/31VDC±0.6V/62VDC±1.2V/124VDC±2.4V | |||||||||||||
High Battery Voltage Recover | 15.0±0.3V/30VDC±0.6V/60VDC±1.2V/120VDC±2.4V | |||||||||||||
CHARGER | Charger Voltage | 14V±0.2V/28V±0.4V/56V±0.8V/112V±1.2V | ||||||||||||
Overcharge Protection S.D. | 15.5VDC/31VDC/62VDC/124VDC | |||||||||||||
Maximum Charge Current | 15A~25A | |||||||||||||
BYPASS & PROTECTION | Nominal Input Frequency | 50Hz or 60Hz | ||||||||||||
Overload Protection(SMPS Load) | IPS automatically shutdown if overload exceeds 120% of normal value for 30 seconds IPS automatically resume work if overload comes back to rated load | |||||||||||||
Output Short Circuit Protection | FUSE | Circuit breaker | ||||||||||||
Bypass Fuse Rating | 10A | 15A | 30A | 50A | ||||||||||
Max Bypass Current | 10A | 15A | 30A | 50A | ||||||||||
MECHANICAL SPECIFICATIONS | Dimensions(W*H*D) | 140*182*380 | 190*350*450 | 260*750*570 | ||||||||||
Net Weight(kg) | 11 | 12 | 24.2 | 27.4 | 29.5 | 33 | 35 | 41 | 47 | 53 | ||||
Shipping Dimensions(W*H*D) | 215*285*465 | 325*473*595 | 480*1030*720 | |||||||||||
Shipping Weight(kg) | 12 | 13.2 | 26.9 | 30.1 | 33.2 | 35.7 | 49 | 55 | 61 | 67 | ||||
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||||||||
Audible Noise | 60dB MAX | |||||||||||||
Display | LED or LCD Optional | |||||||||||||
Loading(20GP/40GP/40HQ) | 950pcs / 2100pcs / 2300pcs | 270pcs / 500pcs / 600pcs | 60pcs / 110pcs / 140pcs |