508W, 53.5 10A Power Supply

China 508W, 53.5 10A Power Supply, Find details about China Power Supply, 150-290VAC from 508W, 53.5 10A Power Supply

Model NO.
BDPAD501M54-1C
Trademark
Goldpower
Specification
359*180*66.9mm
Origin
China
HS Code
8504401400
Model NO.
BDPAD501M54-1C
Trademark
Goldpower
Specification
359*180*66.9mm
Origin
China
HS Code
8504401400
Welcome to use the Customized Power BDPAD501M54-1C from SHANGHAI BEIDIAN. The power can work normally under wide range of input 90V-290VAC, with d -53.5V single output. It is also endowed with short-circuit protection, over-current protection, output over-voltage, output under-voltage and other functions. The power is according with the safety requirements and the information technology equipment safety standards.

Environment
ParameterMinModelMax UnitNote
Work temperature-402555°C 
Storage environment temperature-402565°C 
Relative humidity (RH)5 95% 
Altitude0 4000mLong-term operation available. Max. temperature should be 65ºC, which falls  1.5°C with every1000m increasing
Atmospheric pressure;70 106KPa 
Cooling    Natural cooling
 
Input
ParameterMinModelMaxUnitNote
Input voltage range90110/220290VacAffordable max. input voltage (static): long-term affording valid voltage of 320V sinusoidal wave voltage without damage.
DC input voltage240 380Vdc 
Input frequency4750/6063Hz 
Max input current  7AInput 150Vac, max load 500W
DC input Max current  3A 
Power factor0.98   Rated input, rated load
AC input formatsSingle-phase triplet type 110Vac/220Vac single-phase,110Vac double fire wire input
      
 
Basic Output Features
ParameterMinModelMaxUnitNote
Output voltage range -53.5 Vdc 
Output current range 10 A 
Load regulation  ±1% 
Regulation  ±2% 
Line regulation  ±1% 
Ripple(peak-to-peak value)  200mVRated input/output, testing with each of 0.1uF film capacitor and 10uF high frequency electrolytic capacitor, under band width of 20MHz.
Output power 540 W150-290Vac full voltage range
Output efficiency
 
88  %Input 220VAC, rated output voltage, above 80% rated load  output
80  %Input 110VAC, rated output voltage, above 50% rated load output
Boot start time  8SRated input voltage startup--output voltage found--Setting value
Switch overshoot amplitude  ±5%Full voltage range, full load to min load, No capacitive loads.
Dynamic response overshoot  ±5%Load 25%-50% or 50%-75%-50% load fluctuation
Dynamic response recovery time  200us
Temperature coefficient  ±0.02%/ºC 
Output lasting time10  ms220Vac input, full load output


 
Protection
ParameterMinModelMaxUnitNote
Input under-voltage point  80VAuto recoverable
Input under-voltage recovery point  90VHysteresis not less than 5V
Input over-voltage protection point300  VAuto recoverable
Input over-voltage recovery point290  VHysteresis not less than 5V
Output over-voltage protection point58 60VLock up
Output current-limiting protection10.9 13AAuto recoverable
Short circuit protection   ALong-term short circuit without damage,.
Auto recoverable
Over temperature Protection  100ºCAuto recoverable under environment temperature 60ºC. Power is with thermal protection.
Safety and Insulation Rating
ParameterStandard RequirementsNote
Safety requirementThe design meets with the requirements of latest version UL60950-1,EN60950-1,IEC60950-1,UL50&EN60950-22. Final goods are given TUV, UL, CE approval. 
Input-output3000Vac(4242Vdc)/10mA//1minNo breakdown and flashover, test remove discharge tube
Input-ground1500Vac(2121Vdc)/10mA//1min
Output-ground500Vdc(700Vdc)/10mA//1min
Leak current to earth<3.5mA264Vac input  50HZ input
Insulation resistance10MΩIn normal atmospheric pressure, relative humidity: 90%  Testing voltage: 500v dc  insulation resistance of input-output, input-ground, output-ground shall not be less than 10MΩ
Safety certificationAccording to requirements of IEC60950,UL60950, GB4943-2001 standards. Final goods get UL,TUV,CE and 3C approval
 
UL60950-1;EN60950-1
IEC60950-1;GB4943-2001

 
 
EMC and Others
ParameterStandard
CEEN55022 - Class B  (3dB allowance required)
REEN55022 - Class B (3dB allowance required)
ESDEN/IEC 61000-4-2   EN55024
contract discharge: ±6KV,  air discharge: ±8KV,directive B (Discharge from rack inside to outside)
North Africa: contract discharge: ±8KV,air discharge: ±15KV
Harmonic wave emissionEN/IEC61000-3-2  CLASS A
CSEN/IEC 61000-4-6 LEVEL 3;10V/m,80%AM  Directive A
RSEN/IEC 61000-4-3 LEVEL 3;10V/m,80%AM  Directive A
EFT/BEN/IEC 61000-4-4 ±2 KV Directive B; North Africa; GND terminal ±4 KV
SURGEEN/IEC 61000-4-5 Differential mode: ±6KV, common mode: ±6KV
DIPEN/IEC61000-4-11  dips to 70%Ut, lasting time: 100mS; dips to 40%Ut, lasting time 20ms; dips to 0%Ut, lasting time is 0ms; falling from 0°,45°,90°,135°,180°,225°,270°,315°phases, meeting with directive B; other conditions meet with directive B
Voltage fluctuation and flickeringEN/IEC61000-3-3  Pst1.0 ; P1t0.65;dc3.3%;dmax4%;d(t) value exceeding 3% time500ms
Lightning proofAC input port meets with 8/20us inrush current, differential mode 6KA, common mode 6KA
Reliability (counting)150,000 Hours
Shelf life10 years, sealed electrical capacitor can be kept for 10 years in 40ºC
Yearly returning rate1%
ShakeNormal environmental test: 5- 9Hz; amplitude: 3.5mm;9-200Hz;acceleration spectral density : 10m2/s3;sweep frequency for 5 times in each direction  of 3 axis directions(3*50 minutes)

Packing transportation test: 5-20Hz,1.0m2/s3;20-200Hz:-3dB;total RMS accelerated speed: 0.781Grms, testing time: 30min for each direction.
ShockNormal environmental test: test: half-sinusoidal wave,accelerated speed : 20G,impulse width :11ms; 3 times for each of X,Y,Z directions

Packing transportation test: half-sinusoidal wave,accelerated speed : 300m/s2,impulse width : 6ms; 3 times for each of 6 directions.
CrushNormal environmental test: half-sinusoidal wave,accelerated speed : 20G,impulse width : 11ms;3 times for each of X,Y,Z directions

Packing transportation test: half-sinusoidal wave,accelerated speed : 180m/s2,impulse width : 6ms;100 times each for 6 directions.
FallingNormal environmental test: Weight <10Kg,10-25Kg,25-50kg,50kg; falling height: 0.10m,0.075m,0.05m,0.025m;  face S1,edge E1, E3,angle C degree,C2 falling for one time respectively
Packing transportation test: face, angle, and edge falling, weight 50-100Kg,40-50Kg, falling height:  30cm,40cm.
Acoustic noiseLess than 55dBA; testing distance: 1m,natural cooling
Cooling
  1. Under 65ºC, no wind, 60W natural cooling;(each 30W of 2 output);
  2. Wind available, wind speed 0.5m/s, two air flues(one on the left side, the other on the right side), full load operation within temperature range.
Natural cooling through paster rack cooling, cooling fin, or conductive fin 
SmellingNo abnormal or unhealthy smelling
Dust proof, water proof IP55 dust proof, water proof