Cu /XLPE/Swa/PVC, 0.6/1 Kv, Steel Wire Armored (SWA) Power Cable (BS 5467)

China Cu/XLPE/Swa/PVC, 0.6/1 Kv, Steel Wire Armored (SWA) Power Cable (BS 5467), Find details about China Power Cable, Electric Cable from Cu/XLPE/Swa/PVC, 0.6/1 Kv, Steel Wire Armored (SWA) Power Cable (BS 5467)

Model NO.
CU/XLPE/SWA/PVC
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
Cu/XLPE/Swa/PVC
Brand
Boan
Referred Standard
BS 5467
Rated Voltage
0.6/1 Kv
Number of Cores
2-4
Size Range
4-300 mm2
Class of Conductor
2
Type of Armour
Galvanized Steel Wire
Trademark
DingAn
Specification
SGS, CE
Origin
Jiangsu Yixing, China
HS Code
8544492100
Model NO.
CU/XLPE/SWA/PVC
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
Cu/XLPE/Swa/PVC
Brand
Boan
Referred Standard
BS 5467
Rated Voltage
0.6/1 Kv
Number of Cores
2-4
Size Range
4-300 mm2
Class of Conductor
2
Type of Armour
Galvanized Steel Wire
Trademark
DingAn
Specification
SGS, CE
Origin
Jiangsu Yixing, China
HS Code
8544492100
CU/XLPE/SWA/PVC, 0.6/1 KV, Steel Wire Armored (SWA) Power Cable (BS 5467)
CONSTRUCTION:

Conductor: Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of BS EN 60228.
Insulation: An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 º C at normal operation to BS 7655-1.3.
Bedding: An extruded layer of Polyvinyl chloride (PVC).
Armour: Single layer of round galvanized steel wires.
Outer Sheath: An extruded layer of Polyvinyl chloride (PVC) sheathing compound type TM1 to BS 7655-4.2.

APPLICATION:
For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA:
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. Admissible temperature of conductor at normal operation 90 º C
- Max. Admissible temperature of conductor at short circuit 250 º C for 5 seconds
SectionMax. Conductor ResistanceCurrent RatingOverall DiameterCable Weight
DC at 20AC at 70Laid in GroundLaid in DuctsLaid in Free Air
No. x mm2
Ω/kmΩ/kmAAAmmkg/km
Two Core Cables
4rm4.61005.880051414714.7445
6rm3.08003.930064536115.7520
10rm1.83002.330083708017.1640
16rm1.15001.47001078410619.8930
25rm0.72700.927014010814023.21290
35rm0.52400.669016813516826.51770
Three Core Cables
4rm4.61005.880046374215.3500
6rm3.08003.930058465116.4595
10rm1.83002.330076616919.1815
16rm1.15001.470098769021.51065
25rm0.72700.927013010312026.21665
35sm0.52400.669015812214725.71865
Four Core Cables
4rm4.61005.880046374216.4575
6rm3.08003.930058465118.5795
10rm1.83002.330076616920.4960
16rm1.15001.470098769023.11280
25rm0.72700.927013010312228.21990
35sm0.52400.669015812214728.72335
50sm0.38700.494018514518432.42975
70sm0.26800.343022018022037.44270
95sm0.19300.248026521027340.15375
120sm0.15300.197030524531545.46980
150sm0.12400.160033527537549.98280
185sm0.09910.129037531041054.910103
240sm0.07540.099043536548860.912660
300sm0.06010.081049040556266.515305