China Pure Sine Wave Inverter 1kw 2kw 3kw 4kw5kw 6kw, Find details about China Inverter 1- 6kw/12V or 24V or 48V, Wave Inverter from Pure Sine Wave Inverter 1kw 2kw 3kw 4kw5kw 6kw
MODEL (EP3200) | EP Model | |||||||
1012 | 1024 | 2012 | 2024 | 3024 | 4048 | 5048 | 6048 | |
Line Mode Specifications: | ||||||||
Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
Nominal Input Voltage | 230Vac( selectable) | |||||||
Low Line Disconnect | 155Vac±4% | |||||||
Low Line Re-connect | 164Vac ±4% | |||||||
High Line Disconnect | 272Vac±4% | |||||||
High Line Re-connect | 265Vac±4% | |||||||
Max AC Input Voltage | 270Vrms | |||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
Low Line Frequency Re-connect | 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz; | |||||||
Low Line Frequency Disconnect | 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz; | |||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz; | |||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz;55+0.3Hz for 50Hz; | |||||||
Output Voltage Waveform | As same as Input Waveform | |||||||
Over-Load Protection(SMPSload) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
Efficiency (Line Mode) | >95% | |||||||
Transfer Switch Rating | 30A | |||||||
Transfer Time (Ac to Dc) | 10ms (typical) | |||||||
Transfer Time (Dc to Ac) | 10ms (typical) | |||||||
Charge current | current is adjustable 25% 50% 75% 100%(option) | |||||||
Max Bypass Overload Current | 1kw/2k/3kw: 30A 4kw/5kw/6kw: 40A | |||||||
Invert Mode Specifications: | ||||||||
Output Voltage Waveform | pure sine wave | |||||||
Rated Output Power (VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
Rated Output Power (W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
Power Factor | 1.0 | |||||||
Nominal Output Voltage (V) | 230Vac | |||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | |||||||
Auto tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz | |||||||
Output Voltage Regulation | ±10% rms | |||||||
Efficiency (battery mode) | >90% | |||||||
Over-Load Protection (SMPS load) | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes;(125%<load<150%) ±10%: Fault (shutdown output) after 60s;Load>150% ±10%: Fault (shutdown output) after 20s; | |||||||
Surge rating | 3000VA | 6000VA | 9000VA | 12000VA | 15000 VA | 18000VA | ||
Capable of starting electric motor | 1 HP | 1 HP | 2 HP | 3 HP | ||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||
Bypass Breaker Size | 10A | 30A | 30A | 30A | 30A | |||
Nominal DC Input Voltage | 12V | 24V | 12V | 24V | 24V | 48V | 48V | |
Min DC start voltage | 11V/22V/43V | |||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery | |||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery | |||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery | |||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery | |||||||
Power saver | Load ≤25W | |||||||
Charge Mode Specifications: | ||||||||
Nominal Input Voltage | 230Vac | |||||||
Input Voltage Range | 155-265Vac | |||||||
Nominal Output Voltage | same as input voltage | |||||||
Nominal Charge Current | 35A | 35A | 70A | 35A | 45A | 35A | 40A | 50A |
Charge Current Regulation | ± 5Adc | |||||||
Battery initial voltage | 0 -15.7 Vdc (can operate with 0V battery) | |||||||
Charger Short Circuit Protection | Circuit breaker | |||||||
Over Charge Protection | Bat. V ≥15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60s | |||||||
General Specifications | ||||||||
Safety Certification | CE/SONCAP | |||||||
Safety Certification | FCC | |||||||
Operating Temperature Range | 0°C to 40°C | |||||||
Storage temperature | 15°C below zero to 60°C | |||||||
Operation humidity | 5% to 95% | |||||||
Audible Noise | 60dB max | |||||||
Cooling | Forced air, variable speed fan | |||||||
Size | 1012/1024/2012/2024/2048/3012/3024/3048:580X315X300MM 4048/5048//6048:755X319X288MM |