China Pure Sine Wave on Grid Solar Inverter 2kw to 6kw, Find details about China Grid Tie Solar Inverter, on Grid Solar Inverter from Pure Sine Wave on Grid Solar Inverter 2kw to 6kw
MODEL | PH30-2K | PH30-3K | PH30-4K | PH30-5K | PH30-6K | |
Default Battery System Voltage | 48 VDC | |||||
SOLAR CHARGER & AC CHARGER | PV Open Circuit Voltage(VDC) | 145 VDC | ||||
Max PV Input Power(W) | 2600W | 3200W | 3200W | 6400W | 6400W | |
Max Solar Charging Current(A) | 45A | 60A | 120A | |||
Max AC Charging Current(A) | 40A | 60A | 80A | 100A | 120A | |
Battery | Rated input voltage(VDC) | 48 VDC | ||||
Allowed input DC voltage scope(VDC) | 40 VDC -- 62 VDC | |||||
LV alarm point(VDC) | 42 VDC | |||||
OV alarm point(VDC) | 60VDC | |||||
AC Output | Rated capacity(VA) | 2500VA | 3750VA | 5000VA | 6250VA | 7500VA |
Rated output power(W) | 2000W | 3000W | 4000W | 5000W | 6000W | |
Rated output voltage and frequency (Vac/Hz) | 230Vac / 50Hz | |||||
Rated output current(A) | 8.7A | 13A | 17.4A | 21.7A | 26A | |
Output voltage precision(Vac) | 230 Vac±1% | |||||
Output frequency precision(Hz) | 50 Hz±0.1% | |||||
Rate of wave distortion(THD) (Linearity loads) | Off grid≤2% | |||||
Grid discharge ≤3% | ||||||
Grid charge ≤3% | ||||||
Dynamic response speed(0←→100%) | 20ms | |||||
Power factor | Grid discharge 99.9% & Grid charge 99.9% | |||||
Overload capability | 110%,30 minutes | |||||
125%,1 minutes | ||||||
150%,30 seconds | ||||||
200%,10 seconds | ||||||
Short circuit 5s | ||||||
Grid / Off grid change time | <10ms | |||||
Output wave | sine | |||||
Inverting efficiency 80% resistive loads | ≥92% | ≥93% | ||||
Standby Power Consumption | <2W | |||||
AC Input | AC Input maximum of current(A) | 17.4A | 26A | 34.8A | 43.4A | 52A |
AC Input voltage scope(Vac) | 184Vac ~ 253Vac | |||||
AC Input frequency scope(Hz) | 47.5Hz ~ 51.5Hz | |||||
Display & Protection Function | LED indication | Systematic operation, indication of charge and discharge, indication of fault | ||||
LCD display | output voltage, output current, grid voltage, grid current, voltage of storage battery, load power, chart of capacity | |||||
Protection Function | Input LV protection | |||||
Input OV protection | ||||||
Output overload protection | ||||||
Output Short Circuit Protection | ||||||
Mechanical Specifications | Mounting | Wall mount | ||||
W*H* D(mm)/G.W(kg) | 337*462*183mm/25kg | 337*462*183mm/29.5kg | 370*462*183mm/35kg | 370*537*183mm/47kg | 370*537*183mm/47kg | |
Other | Communication terminal | RS485 / CAN bus | ||||
Operation Temperature Range | -20ºC ~ +50ºC | |||||
Environmental Protection Rating | Indoor(IP20) | |||||
Ambient humidity | 0 ~ 90% relative humidity(non-condensing) | |||||
Altitude | ≤3000m |