China Shear Beam Zemic Load Cell, Find details about China Column Load Cell, Canister Load Cell from Shear Beam Zemic Load Cell
Capacity | L | L1 | L2 | L3 | d | H | W | D | H1 | M |
250lb,500lb, 750lb,1Klb | 130 | 15.7 | 25.4 | 76.2 | 13.46 | 30.2 | 30.7 | 13.4 | 16 | M12-6H 1/2-20UNF-2B |
(5.12) | (0.62) | (1) | (3) | (0.53) | (1.19) | (1.2) | (0.53) | (0.63) | ||
0.5t,1t,2t 2.5K,3K, 4K,5KSE | 130 (5.12) | 15.7 (0.62) | 25.4 (1) | 76.2 (3) | 13.4 (0.52) | 31.23 (1.23) | 31.32 (1.23) | 13.4 (0.53) | 15.75 (0.62) | M12-6H 1/2-20UNF-2B |
3t,5t 2.5KSE,5K, 7.5K,10K,15K | 171 (6.73) | 19 (0.75) | 38.1 (1.5) | 95.2 (3.75) | 20.65 (0.81) | 36.8 (1.45) | 36.8 (1.45) | 20.65 (0.81) | 17.78 (0.7) | M20X2.5-6H 3/4-15UNF-2B |
20K | 222.25 (8.75) | 25.4 (1) | 50.8 (2) | 120.7 (4.75) | 26.9 (1.06) | 49.5 (1.95) | 49.5 (1.95) | 27.56 (1.08) | 24.78 (0.97) | M24X2-6H 1-12UNF-2B |
Capacity | t | 0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.75/1/1.5/2/3/5/7.5/10 | |||
lb | 250/500/750/1K/1.5K/2K/2.5K/2.5KLE/3K/4K/5K/5KSE/7.5K/10K/15K/20K | ||||
Accuracy | C2 | C3 | A5M | B10M | |
Approval | OIML R60 C3 | ||||
Maximum number of verification intervals | n max | 2000 | 3000 | 5000 | 10000 |
Minimum load cell verification interval | v min | Emax/5000 | Emax/10000 | Emax/15000 | Emax/10000 |
Combined error | (%FS) | ≤± 0.030 | ≤± 0.020 | ≤± 0.026 | ≤± 0.050 |
Creep | (%FS/30min) | ≤± 0.024 | ≤± 0.016 | ≤± 0.017 | ≤± 0.040 |
Temperature effect on sensitivity | (%FS/10ºC) | ≤± 0.017 | ≤± 0.011 | ≤± 0.013 | ≤± 0.040 |
Temperature effect on zero | (%FS/10ºC) | ≤± 0.023 | ≤± 0.015 | ≤± 0.014 | ≤± 0.020 |
Output sensitivity | (mv/v) | 3.0±0.008 | |||
Input resistance | (Ω) | 350±3.5 | |||
Output resistance | (Ω) | 350±3.5 | |||
Insulation resistance | (MΩ) | ≥ 5000(50VDC) | |||
Zero balance | (%FS) | 1 | |||
Temperature, compensated | (ºC) | -10~+40 | |||
Temperature,allowed | (ºC) | -35~+65 | |||
Excitation, Recommended | (V) | 5~12(DC) | |||
Excitation,Max | (V) | 18(DC) | |||
Safe overload | (%FS) | 150 | |||
Ultimate overload | (%FS) | 300 |