China Zemic H8c Alloy Steel Load Cell with Capacity 5t, Find details about China Load Cells, Weighing Load Cell from Zemic H8c Alloy Steel Load Cell with Capacity 5t
Maximum capacity(Emax) | 5t | |||||
Accuracy class | C3 | |||||
Approvals | OIML R60 C3 | |||||
Maximum number of load cell intervals(nLC) | 3000 | |||||
Ratio of minimum LC verification interval Y=Emax/Vmin | 10000 | |||||
Combined error | %FS | ±0.020 | ||||
Creep | %FS/30min | ±0.016 | ||||
Temperature effect on sensitivity | %FS/10ºC | ±0.011 | ||||
Temperature effect on zero | %FS/10ºC | ±0.015 | ||||
Output sensitivity(=FS) | mV/V | 3±0.003 2.0±0.002 | ||||
Input resistance | Ω | 350±3.5 | ||||
Onput resistance | Ω | 350±3.5 | ||||
Insulation resistance | MΩ | ≥5000(50VDC) | ||||
Zero balance | %FS | ±1.0 | ||||
Compensated temperature | ºC | -10~+40 | ||||
Operating temperature | ºC | -35~+70 | ||||
Excitation,recommended voltage | V | 5~12(DC) | ||||
Excitation maximum | V | 18(DC) | ||||
Safe overload | %FS | 150 | ||||
Ultimate overload | %FS | 300 | ||||
Recommended torque on fixation | N.m | M12: 100; M18: 200; M24: 700 | ||||
Ingress protection(according to EN 60529) | IP67 |