Medium Voltage XLPE Insulated Armored Power Cable

China Medium Voltage XLPE Insulated Armored Power Cable, Find details about China Cable, Power Cable from Medium Voltage XLPE Insulated Armored Power Cable

Model NO.
YJV32, YJLV32
Material Shape
Round Wire
Range of Application
Construction,Power Station, Underground
Certification
ISO9001, UL
Brand
Rne Da
Voltage
3.6/6kv, 6/10kv(11kv), 12/20kv(24kv), 19/33kv, 26/
Cors
1 or 3 Cores
Cross Section
25mm2-800mm2
Standarad
IEC60245
Certificate
UL,CE,TUV
Trademark
RNE DA
Specification
IEC60245
Origin
Hebei, China
HS Code
85444921
Model NO.
YJV32, YJLV32
Material Shape
Round Wire
Range of Application
Construction,Power Station, Underground
Certification
ISO9001, UL
Brand
Rne Da
Voltage
3.6/6kv, 6/10kv(11kv), 12/20kv(24kv), 19/33kv, 26/
Cors
1 or 3 Cores
Cross Section
25mm2-800mm2
Standarad
IEC60245
Certificate
UL,CE,TUV
Trademark
RNE DA
Specification
IEC60245
Origin
Hebei, China
HS Code
85444921
Medium voltage xlpe insulated armour power cable

1 Application:
 It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting
 
 2 Construction
 
Standards: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armoring:
Single CoreAluminum Wire Armored (AWA)
MultiCore: Steel Wire Armored (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Color: Red or Black
 
3 Using features:
 
1.Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius
Single core - Fixed: 15 x overall diameter
3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
 
Note:
The single core armored cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armor wires of non-magnetical materials should be used.

Medium Voltage XLPE Insulated Armored Power Cable
 Medium Voltage XLPE Insulated Armored Power Cable
Medium Voltage XLPE Insulated Armored Power Cable