China 15s 25A Lithium-Ion Battery Management System BMS for LiFePO4 Battery, Find details about China Battery Management System, BMS from 15s 25A Lithium-Ion Battery Management System BMS for LiFePO4 Battery
Details | Min. | Typ. | Max | Error | Unit | |
Battery Gas | LiFePO4 Battery | |||||
Battery Link | 15S | |||||
Max Input Charging Voltage | 56.25 | ±0.375 | V | |||
Input Charging Current | <10 | A | ||||
Min Output Discharging Voltage | 33 | ±0.750 | V | |||
Continuous Output Discharging Current | 25 | A | ||||
Ambient Condition | Operating Temperature | -40 | 85 | ºC | ||
Humidity (No Water-Drop) | 0% | 90% | RH | |||
Storage Condition | Temperature | -40 | 85 | ºC | ||
Humidity (No Water-Drop) | 0% | 90% | RH | |||
Protection Parameters (for Individual Cell) | ||||||
Over-Charge Voltage Protection (OVP) | 3.75 | ±0.025 | V | |||
Over-Charge Protection Delay Time | 0.5 | 1 | 1.5 | S | ||
Over-Charge Voltage Protection Release (OVPR) | 3.55 | ±0.05 | V | |||
Over-Discharge Voltage Protection (UVP) | 2.2 | ±0.05 | V | |||
Over-Discharge Delay Time | 0.5 | 1 | 1.5 | S | ||
Over-Discharge Voltage Protection Release (UVPR) | 2.7 | ±0.10 | V | |||
Over-Current Discharge Protection (OCDP1) | 100 | ±10 | A | |||
Over-Current Protection Delay Time (OCPDT1) | 0.5 | 1 | 1.5 | S | ||
Over-Current Discharge Protection(OCDP2) | 200 | ±20 | A | |||
Over-Current Protection Delay Time(OCPDT2) | 0.05 | 0.10 | 0.15 | S | ||
Over-current protection release method | Disconnect load recovery | |||||
Short circuit current protection | 400 | ±50 | A | |||
Short circuit current protection delay time | 200 | 250 | 300 | uS | ||
Over-current charge current protection | 20 | ±10 | A | |||
Discharging High Temperature(Optional) | 82 | ±4 | ºC | |||
Discharging High Temperature Protection Release | 58 | 62 | 66 | ºC | ||
Charging High Temperature(Optional) | 55 | ±4 | ºC | |||
Charging High Temperature Protection Release | 48 | 52 | 56 | ºC | ||
Charging Low Temperature(Optional) | -7 | ±4 | ºC | |||
Charging Low Temperature Protection Release | -6 | -2 | 2 | ºC | ||
Temperature protection detection delay time | 1.5 | 3 | 5.5 | S | ||
Temperature protection release detection delay time | 1.5 | 3 | 5.5 | S | ||
Charge and discharge state switching delay time | 200 | 500 | 650 | mS | ||
Balance opening voltage | 3.5 | ±0.025 | V | |||
Undervoltage load locking | Yes | |||||
PCBA Size | < 103×60×12 | mm |