Air Cooler Precision Air Conditioner Server Room High Configuration Split Type Air Conditioner

China Air Cooler Precision Air Conditioner Server Room High Configuration Split Type Air Conditioner, Find details about China Air Cooler AC, Server Room Air Conditioner from Air Cooler Precision Air Conditioner Server Room High Configuration Split Type Air Conditioner

Model NO.
room air conditioner
Noise Level
Ordinary
Application Fields
Server Room
Mounting
in Row
Lifetime
10~15 years
Certification
RoHS, ISO, CE
Condition
New
Type of Compressor(Standard)
DC Inverter
Voltage
380/400
Frequency
50/60
Trademark
kstar
Specification
26.9kw, 32.7kw, 37.2kw, 41.8kw, 52.8kw, 61.7kw
Origin
China
HS Code
8415812090
Model NO.
room air conditioner
Noise Level
Ordinary
Application Fields
Server Room
Mounting
in Row
Lifetime
10~15 years
Certification
RoHS, ISO, CE
Condition
New
Type of Compressor(Standard)
DC Inverter
Voltage
380/400
Frequency
50/60
Trademark
kstar
Specification
26.9kw, 32.7kw, 37.2kw, 41.8kw, 52.8kw, 61.7kw
Origin
China
HS Code
8415812090
StationAir Series
With the function of constant temperature and humidity, StationAir series precision air conditioners are designed with large air volume and high sensible heat ratio to meet the needs of professional computer room; The design that operation for 365 day* 24 hours non-stop efficient matches cooling system with a large area of evaporator to ensure all-weather optimal energy-saving operation.
Application: Small-medium data center, Equipment room, laboratory, storage room.
General Features

Total cooling capacity: 5kW~20kW

High power-efficiency design, EER of standard machine is above 3.0; EER of High power-efficiency machine is above 3.5

Supply upflow, downflow, upper-front flow, lower-front flow

R410 environment-friendly refrigerant

Stepless speed regulating outdoor fan system solve low frequency noise problem

Electronic expansion valve is standard equipment, and this make it more adaptive for environment

Patent fan design can reduce 30% energy. The fan supports sinking deployment and non-sinking deployment

RS485, 5-meters copper pipe, refrigerant and bracket of outdoor unit are standard equipment for cooling capacity below 12.5KW
 

Technical Specification
DX Unit 
ST***unit57
 Unit Configuration - Single CoolingConstant
 Temperature
Constant 
Temperature 
and Humidity
 Single Cooling   Constant
 Temperature
Contant 
Temperature 
and Humidity
Total Cooling
 Capavity
kW5.57.5
Sensible Cooling
 Capavity
kW5.26.8
Air volumem³/h20002250
Sensible heat ratio/0.950.91
Heating capacityKW 33 33
Humidyfying 
 capacity 
kg/h  2.5  2.5
Number of 
compressors
Pcs11
Number of FansPcs11
VoltageV220~240220~240380~415220~240220~240380~415
FrequencyHz5050
PhaseP113113
Full-load Current A11.623.215.515.326.919.2
Unit Weightkg105 110120 115 120 130
Unit Widthmm550550
Unit Depthmm450450
Unit Heightmm17501750
DX Unit      
ST***unit121720
 Unit Configuration - Single CoolingConstant
 Temperature
Constant 
Temperature
 and Humidity
Constant
 Temperature
Constant
 Temperature
 and Humidity
Total Cooling 
Capavity
kW12.517.520.5
Sensible Cooling
 Capavity
kW11.315.818.6
Air volumem³/h285050006200
Sensible heat ratio/0.90.90.91
Heating capacityKW 4466
Humidyfying capacity kg/h  44.54.5
Number of compressorsPcs111
Number of FansPcs111
VoltageV380~415380~415380~415
FrequencyHz505050
PhaseP333
Full-load Current A11.316.516.523.724.7
Unit Weightkg165170  180280300
Unit Widthmm650750750
Unit Depthmm550700700
Unit Heightmm185019001900
Supporting Outdoor unit 
KCS***unit710182428
Heat
 Exchange 
Capability
kw7.610.418.123.827.2
VoltageV220220220220220
FrequencyHz5050505050
PhasePcs11111
Full-load
 Current 
A0.50.71.42.72.7
Noise dB(A)38.543.943.654.952.9
Unit Weightkg384860117124
Unit Widthmm877967101416001400
Unit Depthmm340398375975975
Unit Heightmm6088071244650650
Foot stool
 Height
mm   455455
    Note:
               parameter table.
               Air-cooled unit data based on 24°C,50%RH indoor return airtemperature.
               The noise data is sound pressure level value of 10m free field.
               ST005,ST007 and ST012 is prefilled refrigerant,and supplied with 5m connecting copper pipe and mounting brackets of 
outdoor unit.
               Specifications are subject to change without prior notice.

Air Cooler Precision Air Conditioner Server Room High Configuration Split Type Air ConditionerAir Cooler Precision Air Conditioner Server Room High Configuration Split Type Air ConditionerAir Cooler Precision Air Conditioner Server Room High Configuration Split Type Air Conditioner


Air Cooler Precision Air Conditioner Server Room High Configuration Split Type Air ConditionerAir Cooler Precision Air Conditioner Server Room High Configuration Split Type Air ConditionerAir Cooler Precision Air Conditioner Server Room High Configuration Split Type Air Conditioner