China Cell Counter Hematology Analyzer Price Automated Hematology Analyzer Cormay Mslab20, Find details about China Hematology Analyzer, Blood Cell Counter from Cell Counter Hematology Analyzer Price Automated Hematology Analyzer Cormay Mslab20
Opportunity to replace 3-diff hematology analyzer
Performance
High Stability & Accuracy
l Use the most advanced binuclear embedded digital circuit system, to make the analytical ability great and stable
l 2 counting channels of WBC and RBC, to make the test results more accurate and less cross- contamination
l Use CPLD technology in data processing, to avoid the interference of electromagnetic signals
Reliable Operation System
l ARM intelligent micro-processing technology
l Data analysis: intelligent pulse formulation technology
l Classification: floating landmark technology
l Module design, fast maintenance
User-friendly System
l 10.4''large color LCD displays main menu and all parameters & color histograms in one screen
l Brief operation instruction built-in software, easy for user to view
l Separate module design, very simple mechanical structure, easy maintenance
l Self check for hardware, alarm for error
l Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function
Technical Features
l 2 counting mode: whole blood, pre-dilution blood
l Sample pre-dilution: internal diluter, add 1ml diluent automatically by the needle, no need to add diluent manually to avoid deviation.
l Calibration: automated or manual
l QC: comprehensive QC program, forming and printing the histogram automatically
l Block removal: Real time monitor, high ignition, soak, flush and back flush
Technical Specifications | |
Principle | Optical solid state LASER scattering Wide angle light scatter,High efficient light collector(patented) Electrical Impedance,Double hydrodynamic focusing |
Parameters | LYM#, Mon#, Neu#, Bas#, Eos#, LYM%, Mon%, Neu%, Bas%, Eos%, Lx, Ly, Nx, Ny, WBC, RBC, Hb, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD*, Plt, Pct, MPV, PDW 1 Scattergrams:WBC/BASO Interpreted Scattergram 4 Histograms:RBC,PLT,WBC,cyto For research only:ACY% , ALY# , LIC% , LIC# , NIL% , NIL# |
Throughput | Up to 90 samples per hour/(Auto sample mode/Open sample mode ≥90samples per hour) |
Sample Volume | Prediluted: 20µL Whole blood: 10µL |
Sample types | Whole blood,PLT only,HB only,Capillary predilution,Diluent,Control,Calibrator |
Display | 12.1Inch Touch Screen |
Storage | Up to 100,000 results including numeric and graphical information |
Printout | External Laser printer/Inkjet printer, various printout formats and user-defined formats |
Carryover | WBC<0.5%, RBC<0.5%, HGB<0.5%, PLT<0.8% |
Mult-language | Chinese,English for optional and others can be customized |
Working Conditions | Temperature: 10-35ºC, Humidity: ≤30%~85% Atmospheric pressure: 70Kpa-106Kpa Power supply: AC100V-240V, 50/60Hz |
Dimension | Instrument:532mmx400mmx520mm Package: 696mmx576mmx696mm |
Weight | Net:28KG Gross:32KG |