Defibrillator Monitor Medical Equipment PT- 9000b

China Defibrillator Monitor Medical Equipment PT-9000b, Find details about China Defibrillator, Medical Equipment Defibrillator from Defibrillator Monitor Medical Equipment PT-9000b

Model NO.
PT-9000B
SpO2 Display
SpO2 Value, Pulse Histongram, Waveform, Pulse
Trademark
Seeuco
Specification
CE
Origin
Jiangsu, China
Model NO.
PT-9000B
SpO2 Display
SpO2 Value, Pulse Histongram, Waveform, Pulse
Trademark
Seeuco
Specification
CE
Origin
Jiangsu, China
Defibrillator Monitor Medical Equipment PT-9000B
1. Cardic Defibrillator Monitor
2. Automated External Defibrillator
3. Biphasic Defibrillator Monitor

ECG: ECG lead: I, II, III, Avr, Avl, Avf, V1~V6
S-T segment analysis: -2.0~2.0mv
Protegtion: Withstand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation
ECG lead/cable: General lead/cable for adult, pediatric and neonatal patients
NIBPMethod: Automatic oscillation
Working mode: Manual/Automaic
Measurement range: Adult 10~250mmHg, Pediatric10~250mmHg, Neonatal 10~135mmHg
TEMPMeasurement range: 20~45° C
Resoluion: 0.1° C
RESPMeasurement method thoracic impedance
SpO2 Display: SpO2 value, pulse histongram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
PulsePulse range: 0~300bpm
Pulse accuracy: ± 2bpm
DefibrillatorNon-synchronizer: Outlife difibrillator
Sine wave: Monophasic technology
Energy: 0, 20, 50, 100, 160, 250, 300, 360 joule
Charging time: At 360J less than 10 sec
Paddle options: Reusable extermal adult paddles
PowerAC and its intemal NIMH battery


Defibrillator Monitor Medical Equipment PT-9000bDefibrillator Monitor Medical Equipment PT-9000bDefibrillator Monitor Medical Equipment PT-9000b
ECG ECG lead: I, II, III, Avr, Avl, Avf, V1~V6
S-T segment analysis : -2.0~2.0mv
Protegtion: Withstand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation
ECG lead/cable: General lead/cable for adult,pediatric and neonatal patients
NIBP Method: Automatic oscillation
Working mode: Manual/Automaic
Measurement range: Adult 10~250mmHg, Pediatric10~250mmHg, Neonatal 10~135mmHg
TEMP Measurement range: 20~45°C
Resoluion: 0.1°C
RESP Measurement method thoracic impedance
SpO2 Display : SpO2 value,pulse histongram,waveform,Pulse
Range: 0~99%for adult,pediatric and neonatal patients
Probe : standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse Pulse range : 0~300bpm
Pulse accuracy: ±2bpm
Defibrillator Non-synchronizer: outlife difibrillator
Sine wave: monophasic technology
Energy: 0, 20, 50, 100, 160, 250, 300, 360 joule
Charging time : at 360J less than 10 sec
Paddle options : reusable extermal adult paddles
Power AC and its intemal NIMH battery