Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP ( DM7000 )

China Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP (DM7000), Find details about China Defibrillator Monitor, Defibrillator from Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP (DM7000)

Model NO.
DM7000
Waveform
Biphasic
Electrode Impedance Measurement Range
0-250 Ohms
Patient Connection
3-Lead ECG Cable, or 5-Lead ECG Cable, Paddles
Lead Time
Within 7 Days
Warranty
12 Months
Lead Selection
Displayed on Monitor, Paddles, I, II, III, AVR, AV
ECG Size
0.25, 0.5, 1, 1.5, 2, 4 Cm/Mv Diplay on Monitor.
Heart Rate
20-300bpm
Trademark
PIOWAY
Specification
303*216*89mm
Origin
China
Model NO.
DM7000
Waveform
Biphasic
Electrode Impedance Measurement Range
0-250 Ohms
Patient Connection
3-Lead ECG Cable, or 5-Lead ECG Cable, Paddles
Lead Time
Within 7 Days
Warranty
12 Months
Lead Selection
Displayed on Monitor, Paddles, I, II, III, AVR, AV
ECG Size
0.25, 0.5, 1, 1.5, 2, 4 Cm/Mv Diplay on Monitor.
Heart Rate
20-300bpm
Trademark
PIOWAY
Specification
303*216*89mm
Origin
China

CE, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP(DM7000)

Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP (DM7000)




Product Description:
DM7000 is a defibrillation device, which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). 

Display 

Screen Type:High-resolution display 
Screen Size:7 inches(17.7 cm) diagonally 
Sweep Speed:25mm/sec 
Information:Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy. 


Defibrillator 

Waveform:Biphasic 
Charge Time:Less than 7 seconds with a new fully charged battery. 
Energy Display:Monitor display indicates both selected and delivered energy. 
Charge Prompt Type:Voice and visual prompts. 
Electrode Impedance Measurement Range:0-250 ohms. 


ECG Monitoring 
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles. 
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. 
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. 
Heart Rate: 20-300BPM. 
Heart Rate Alarm: On/Off displayed on monitor, user-selectable. 
Smart Alarms: Beeper/voice prompts indicate shockable rhythm. 

Battary 
Type: Rechargeable, Ni-MH battery, 12V. 
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. 

SpO2 Module 
Measurement Range: 30~100%, ±2% between 80%~90%, others ±5% 
Alarm Range: User set high limit and low limit. 
Alarm Accuracy: ±10% within setting values. 
Alarm time Accuracy: less than 12 sec. 

Recorder 
Paper: 50mm thermal. 
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay. 
Printing Method: High-resolution, thermal print head. 
Print-out Modes: Manual or automatic, user-configurable. 
On/Off Control: Front panel and paddle. 
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. 

AED Mode 
AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts. 
Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms. 
Charge Control: Control on device front panel, press key on paddle. 
Prompts: Voice and visual prompts. 

Manual Mode 
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. 
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.


Shipping & Packing:
Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP (DM7000)Ce, ISO Approved Biphasic Defibrillator Monitor with SpO2 ECG and NIBP (DM7000)


Contact us: