8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner

China 8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner, Find details about China Precision Air Conditioner, 8000CMH Precision Air Conditioner from 8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner

Model NO.
JH/JHF
Mounting
Floor Standing
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
Refrigerant
R22/407c/410A
Product Name
8000CMH Airflow Precision Air Conditioner Unit Use
Cooling Capacity
7-125kw
Air Flow
1500-34000 CMH
Trademark
Head-Power
Transport Package
Stretch Roll Film, EPE, Wooden Package
Specification
Customize
Origin
China(Mainland)
Model NO.
JH/JHF
Mounting
Floor Standing
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
Refrigerant
R22/407c/410A
Product Name
8000CMH Airflow Precision Air Conditioner Unit Use
Cooling Capacity
7-125kw
Air Flow
1500-34000 CMH
Trademark
Head-Power
Transport Package
Stretch Roll Film, EPE, Wooden Package
Specification
Customize
Origin
China(Mainland)

1. Precise and reliable
Careful design, rigorous laboratory testing, and comprehensive quality control to ensure that the unit has excellent reliability;
Parts of the world-renowned brands, ensuring high reliability and service life;
Intelligent microprocessor control system, which enables the unit is always running at its best.

2. Constant temperature and humidity
Telecom Cabinet Precision Air Conditioner can accurately control the temperature (accuracy ± 1 ° C), humidity (± 5%) to adapt to all-day job requirements;


Telecom Cabinet Precision Air Conditioner equipped with a frontal area of the evaporator, to reflect the amount of wind, the small enthalpy difference, to produce the greatest sensible cooling capacity, so that the indoor environment, easy to maintain the equilibrium of temperature and humidity;

3. Variety of options
Telecom Cabinet Precision Air Conditioner, with conventional constant temperature and humidity control is flexible, applicable to the general (conventional) constant temperature and humidity requirements of the occasion;


Telecom Cabinet Precision Air Conditioner, can be installed on the ceiling applies to the room space is small or there is no dedicated room small-scale temperature and humidity region of space;


Telecom Cabinet Precision Air Conditioner, communication base stations, telecommunications rooms, data center temperature and humidity control accuracy and operational stability have very high requirements of the occasion;


Telecom Cabinet Precision Air Conditioner, an increase of the purification function, applicable to the purification occasions such as medical operating rooms, electronic workshop;


Non-standard series, to provide customers with the most satisfactory products. For example: The ultra-high precision (precision of temperature control ± 0.3 ° C, humidity control accuracy of ± 2%); Heating, humidification form; Cryogenic temperature and humidity, or large temperature difference between temperature and constant temperature and humidity; Long piping, ultra-high hydrostatic; Integrated design, waste heat recovery.

4. Other features
Variety back to the wind (on the air: The hood / duct or directly from the unit at the top of the air; Under the air: And sent to all parts of the engine room through the raised floor plenum chamber);


Configure the removable electrode humidifier, quickly produce clean steam, optional electric humidifier scene according to user requirements;


G4 level of air filters, filter effects, to meet the conventional cleanliness requirements, and can be equipped with higher cleanliness of the F8-level air filter;

Telecom Cabinet Precision Air Conditioner  electric heating or PTC electric heating, high heating efficiency, to increase the power to adapt to the use of the alpine region, multiple protection so that the heating is more safe and reliable; 
      

 

Product information:

 

                                       Telecom Cabinet Precision Air Conditioner

Indoor   Model No.

JH/JHF

 

Unit Performance

Cooling Type

Water-cooled/Air-cooled

Cooling capacity

kW

6.71~146

Electric heating capacity

kW

4.5~56

Cooling consumed power

kW

2.7~50.3

Air flow

m3/h

2200~34000

External static pressure

Pa

30~80

Power supply

 

220/380/460V-3N-50/60Hz

Refrigerant

 

R22/R407c/R410a

Indoor unit

Fan way

Upper/Front/Down   supply

Motor power

kW

0.18~11

Humidification

Humidifying

4~25Kg/h

Power

kW

3.7~18.75

Noise level

dB(A)

≤53~72

Outdoor   Model No.

SW

 

Compressor

Type

Rotor/Scroll

Compressor Power

kW

2.25~36

Condenser

Type

Copper tube aluminum fins

Blower power

kW

0.37~4.4

Noise level

dB(A)

<62~69

Connection tube

Gas tube(mm)

Φ12.7/Φ15.9/Φ19.1

Gas tube Quantity

1~5pcs

 

Liquid tube(mm)

Φ9.52/Φ12.7

 

Liquid tube Quantity

1~5pcs

 

Connection

Flare opening

 

Note:

  

1. Return air vent are equipped with G4 air   filter.

2. Control temperature   range between 18-32ºC, accuracy of ±0.5ºC.

3. Humidity control   range of 40~80%, with an accuracy of ± 3%.

4. Compressors are put indoor units.


 8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner

8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner
8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner

8000CMH Airflow Precision Air Conditioner Unit Used in Sever Room Air Conditioner