Photoelectric Smoke Detector Fire Alarm ( SD119 )

China Photoelectric Smoke Detector Fire Alarm (SD119), Find details about China Photoelectric Smoke Detector, Photoelectric Smoke Alarm from Photoelectric Smoke Detector Fire Alarm (SD119)

Model NO.
SD119-2
Dimensions
100mm(Dia.)*46mm(Ht) with Base
Certificate
UL/En
Alarm Indicator
LED Continuously Emitting Red Light
Ceiling Spacing
40-50 Foot Rating for Heat Sensor
Temperature Range
-10°c to 50°c
Name
Photoelectric Smoke Detector Fire Alarm
Humidity
0 to 95% Rh, No Condensation or Icing
Smoke Sensitivity
0.98--2.40%/FT Obscuration (UL) ; 0.08--0.14 dB/M
Trademark
Sentek
Transport Package
100PCS/Carton
Specification
UL/EN
Origin
Ningbo China
HS Code
8531901000
Model NO.
SD119-2
Dimensions
100mm(Dia.)*46mm(Ht) with Base
Certificate
UL/En
Alarm Indicator
LED Continuously Emitting Red Light
Ceiling Spacing
40-50 Foot Rating for Heat Sensor
Temperature Range
-10°c to 50°c
Name
Photoelectric Smoke Detector Fire Alarm
Humidity
0 to 95% Rh, No Condensation or Icing
Smoke Sensitivity
0.98--2.40%/FT Obscuration (UL) ; 0.08--0.14 dB/M
Trademark
Sentek
Transport Package
100PCS/Carton
Specification
UL/EN
Origin
Ningbo China
HS Code
8531901000

Specification: 

Smoke Sensitivity:

per UL268 or EN54-7 

Ceiling Spacing:

50 foot rating for heat sensor (55degree)

Reset Voltage:

less than 1 volt

Reset Time:

less than 1 second

Alarm Indicator:

LED continuously emitting red light

Remote Output:

25 mA max., diode gate

Temperature Range:

-10°C to 50°C

Permissible Current:

80mA maximum

Humidity:

0 to 95% RH, no condensation or icing

Alarm Contact:

(for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

Dimensions:

100mm (dia) x 46mm (ht) with base

Weight:

130g/set with base

Photoelectric Smoke Detector Fire Alarm (SD119)

Photoelectric Smoke Detector Fire Alarm (SD119)
 

The range includes:

SD-119-2 :2 wire photoelectric smoke alarm

SD-119-2L :2 wire photoelectric smoke alarm with remote LED output

SD-119-2H :2 wire photoelectric smoke and heat alarm

SD-119-2HL :2 wire photoelectric smoke and heat alarm with remote LED output

SD-119-4-12/24: 4 wire photoelectric smoke alarm (12/24VDC)

SD-119-4B-12/24 :4 wire photoelectric smoke alarm with Buzzer (12V/24DC)

SD-119-4AR-12/24 :4 wire photoelectric smoke alarm with auto-reset function (12/24VDC)

SD-119-4ARB-12/24 :4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24VDC)

SD-119-4H-12/24: 4 wire photoelectric smoke and heat alarm (12V/24VDC)

SD-119-4HB-12/24 :4 wire photoelectric smoke and heat alarm with Buzzer (12/24VDC)

SD-119-4HAR-12/24 :4 wire photoelectric smoke and heat alarm with auto-reset function (12/24VDC)

SD1194HARB12/24 :4 wire photoelectric smoke and heat alarm with autoreset function with Buzzer (12/24VDC

Feartures:

1) Advanced detection and discrimination algorithms 
2) Easy installation and maintenance 
3) Polished low-profile housing design 
4) Durable sensor head, no need for replacement 
5) SMD circuit board design: satisfactory quality and reliability guaranteed 
6) Integrated heat detector for SD119-2H and SD119-4H models 
7) N/C (normal / close) and N/O (normal / open) relay output ways for option 
8) AR (auto reset) function for security systems (optional for 4-wire models) 
9) Sensor base: standard and Schottky diode style for option
10) With two LED, more 360 degree visual angle

Related Product
Photoelectric Smoke Detector Fire Alarm (SD119)
Company Information
Photoelectric Smoke Detector Fire Alarm (SD119)