25 kvar Low Voltage Cylindrical Capacitor to Power Factor Correction

China 25 kvar Low Voltage Cylindrical Capacitor to Power Factor Correction, Find details about China Capacitor, Power Capacitor from 25 kvar Low Voltage Cylindrical Capacitor to Power Factor Correction

Model NO.
BKMJ
Electrolyte
Polypropylene
Usage
Low Frequency Bypass
1-60kvar ,50/60Hz
220VAC ,370VAC ,400VAC ,440VAC ,525VAC ,690VAC
Small Size ,Low Loss
Compensate Factor
Dry Type Non-Pollution;,
Three Phase or Single Phase
Cylinder Type
OEM &ODM
CE ,ISO9001,RoHS ,IEC60831
24 Months Warranty Time
Trademark
BSD
Specification
1-40KVAR
Origin
China,
HS Code
85321000
Model NO.
BKMJ
Electrolyte
Polypropylene
Usage
Low Frequency Bypass
1-60kvar ,50/60Hz
220VAC ,370VAC ,400VAC ,440VAC ,525VAC ,690VAC
Small Size ,Low Loss
Compensate Factor
Dry Type Non-Pollution;,
Three Phase or Single Phase
Cylinder Type
OEM &ODM
CE ,ISO9001,RoHS ,IEC60831
24 Months Warranty Time
Trademark
BSD
Specification
1-40KVAR
Origin
China,
HS Code
85321000
25 kvar Low Voltage Cylindrical Capacitor to Power Factor Correction25 kvar Low Voltage Cylindrical Capacitor to Power Factor CorrectionBKMJ series power capacitor is with explode-proof! The device is mainly suitable for low voltage power network to improve power factor,reduce reactive loss and better the voltage  quality.

Series

Power Factor Capacitor

Rated Voltage Range

From 220-1000 VAC

Connection

3 phase (1 phase on request)

Frequency

50/60 Hz.

PowerRange

1-30 Kvar

Dielectric

Metalized polyprolilene film

Discharge Resistors

Built in automatic discharge resistors included, less than 75V within 3 minutes

 after de-energizing the capacitor

Tolerance

±5%

Maximum Ambient Temperature

 -25 ºC--50ºC  (Other temperature range on request)

  Average temperature within 24 hours below 50ºC&average

  temperature with a year below 30ºC

Max. Relative Humidity

≤90%  

Max. Altitude

≤2000m (Other altitude on request

Over Voltage Tolerance

1.1   UN  (8 hours max. in every 24 hours)

1.15 UN  (30 minutes in every 24 hours)

1.2 UN  (5 minutes in every 24 hours)

1.3 UN  (1 minutes in every 24 hours)

Over Current  Tolerance

30% permanently

Max. Surge Current

200 times of rated current

Dielectric Loss

≤0.2 Watt / Kvar

Voltage Test

Between terminals: 2.15 Un for 10 seconds.

Between terminals to container:  3000VAC for 10 seconds

Safety System

Self protection device

Case Material

Rust-proof tinplate

Execution

Indoor, minimum distance between units  : 50mm

Standard

IEC60831 / GBT12747