Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS

China Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS, Find details about China Controller, Control Panel from Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS

Model NO.
CM-RS232-485 CM-LTE/GPS EM-BI08-EFCP
Product Name
Deep Sea Controller Dse7320
LED
Yes
Generator Type
Diesel Engine Generator
Trademark
Baishan Power
Transport Package
Carton
Specification
184*137mm
Origin
China
HS Code
8503009090
Model NO.
CM-RS232-485 CM-LTE/GPS EM-BI08-EFCP
Product Name
Deep Sea Controller Dse7320
LED
Yes
Generator Type
Diesel Engine Generator
Trademark
Baishan Power
Transport Package
Carton
Specification
184*137mm
Origin
China
HS Code
8503009090

Diesel generator control Modules 6020 control panel

The DSE 6120 MKII is an Auto Mains (Utility) Failure Control Module developed to provide a wide range of operating and monitoring features for single diesel and gas gen-sets. 

OVERALL SIZE
216 mm x 158 mm x 43 mm (8.5" x 6.2" x 1.5")

PANEL CUTOUT SIZE
184 mm x 137 mm (7.2" x 5.3")

MAXIMUM PANEL THICKNESS
8.0mm (0.3")

WEIGHT
0.5kg

PRODUCT VARIANTS
6120-03 - 6120 MKII Auto Mains (Utility) Failure Control Module


Details Show
Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS
Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS
 

SPECIFICATIONS
-------------------------------------------------------------------------------------------------
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous


CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained
during cranking.


MAXIMUM OPERATING CURRENT
100 mA at 12 V, 105 mA at 24 V

MAXIMUM STANDBY CURRENT
60 mA at 12 V, 55 mA at 24 V

MAXIMUM SLEEP CURRENT
40 mA at 12 V, 35 mA at 24 V

 
INPUTS
DIGITAL INPUTS A to F
Negative switching

ANALOGUE INPUT A
Configurable as:
Negative switching digital input
0 V to 10 V
4 mA to 20 mA
0 Ω to 240 Ω

ANALOGUE INPUTS B to D
Configurable as:
Negative switching digital input
0 Ω to 480 Ω ­­

 
OUTPUTS
OUTPUT A (FUEL)                                                         OUTPUT B (START)
10 A short term, 5 A continuous,                                     10 A short term, 5 A continuous,
at supply voltage                                                              at supply voltage

AUXILIARY OUTPUTs C, D, E &F
2 A DC at supply voltage ­­


GENERATOR&MAINS(UTILITY)
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

 

 
Factory view:



Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS
Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS




Diesel Generator Controller Comap Genset Controller Amf8 Amf9 Il3 Mrs11 Mrs16 Amf20 Amf25 Il3 Mrs16 with RJ45 Cm-Ethernet Cm-Gp Ib-Lite RS232 RS485 4G GPS